Verne & Ellsworth Hann is renowned for outstanding HVAC and plumbing services! Being in business since 1907 makes us one of the oldest family-run companies in Cleveland Heights, OH. We offer the finest heating, air conditioning, plumbing, and boiler services to residents of Cleveland Heights.
To schedule top HVAC and plumbing services in Cleveland Heights, OH, call Verne & Ellsworth Hann at (216) 932-9755!

Dependable Heating & Cooling Services
Verne & Ellsworth Hann’s exceptional technicians can install, replace, repair, and maintain your heating or cooling system in Cleveland Heights, OH. You get consistently prompt, respectful service, no matter what type of issue you have.
We offer services for:
- Ductless mini-splits: This cost-effective, energy-efficient method of heating and cooling can be set for specific areas of your home, called zones, instead of having your whole house at one temperature.Â
- Heat pumps: A heat pump heats and cools your home. It’s environmentally safe, inconspicuous, and saves money. Our technicians and technology keep your heat pump working.
- Furnaces: Verne & Ellsworth Hann keeps your home warm in Cleveland Heights, OH! Our installation, repair, and maintenance services ensure your gas or electric furnace runs throughout the coldest Ohio winters.
- Boilers: We are the boiler specialists you want when your boiler requires installation, repair, or replacement. When you experience thermostat issues, system leaks, or lack of heat, turn to Verne & Ellsworth Hann!
- Packaged units: These combine heating and cooling components into a single, convenient unit, conserving space. If your packaged unit in Cleveland Heights, OH, needs to be installed, replaced, repaired, or maintained, Verne & Ellsworth Hann will do it!
Air Quality & Ductwork Services in Cleveland Heights
Excellent indoor air quality helps maintain good health. Verne & Ellsworth Hann’s indoor air quality solutions feature up-to-date technology so the air in your Cleveland Heights, OH, home is as pure as possible.
We handle installation, replacement, repair, and maintenance for:
- Air scrubbers: An air scrubber eliminates dust, pollutants, odors, and other unwanted particles from the air. It can be connected to your ductwork.
- Air purifiers: We provide state-of-the-art technology, like using UV light, to keep your air free of odors, particulates, germs, and mold.
- Whole-house humidifiers: Arid air causes issues with your eyes, mouth, nose, and lips. A whole-house humidifier maintains an ideal comfort level all the time.
Let Verne & Ellsworth Hann improve the indoor air quality of your Northeast Ohio home. Contact our team at (216) 932-9755!
Exceptional Plumbing Services
Since 1952, Verne & Ellsworth Hann has provided first-class plumbing services in Cleveland Heights, OH, addressing:
- Water heaters: We install, replace, and repair tankless, gas, and electric water heaters.
- Water lines: When there are soggy areas in your yard or your tap water is discolored, call us for water line installation, replacement, or repair!
- Gas lines: Problems with your gas line are dangerous. Exit your home immediately, contact your utility company, and let us pinpoint the issue and restore your peace of mind.
- Bathroom & kitchen plumbing: Don’t put up with a broken faucet, malfunctioning garbage disposal, or overflowing toilet! We’ll find the problem fast and correct it.
Verne & Ellsworth Hann is your source for outstanding plumbing services in Cleveland Heights, OH! Call (216) 932-9755 to schedule services today!
Choose Verne & Ellsworth Hann in Cleveland Heights, OH
You can trust Verne & Ellsworth Hann as your HVAC and plumbing partner in Northeast Ohio, including Cleveland Heights. We believe in professionalism, integrity, and transparency. Our licensed and insured techs uphold those standards and are happy to serve you!
We earned the Angi Super Service Award and Best of the Heights Award because of our knowledge, responsiveness, and dedication to satisfying each customer.
Call Verne & Ellsworth Hann at (216) 932-9755 to schedule HVAC or plumbing services in Cleveland Heights, OH, today!
Recent Jobs and Reviews in Cleveland Heights, OH
Job Locations and Reviews
Opened wall in third floor stairwell to access and expose deteriorated galvanized hot water supply piping. Removed existing galvanized riser and replaced with new copper piping to restore proper water supply. Installed compression shutoff valve and escutcheon for code compliance and future serviceability. Tested system for leaks and verified proper operation of all fixtures.
Performed comprehensive tune-up on 5-year-old furnace system currently operating normally. Conducted combustion analysis testing using digital analyzer, measuring oxygen levels (21.0% ambient, 0.2% in flue), carbon monoxide (0 ppm ambient, 8 ppm in flue), carbon dioxide (7.2%), and temperature readings (137.2°F and 105.1°F at different test points). All combustion readings within acceptable parameters for safe and efficient operation. System confirmed to be functioning properly with no issues identified.
Performed preventive maintenance on two residential cooling systems, one located in the basement and one in the attic. Connected Testo 550 digital manifold gauges to measure system performance on R410A refrigerant systems. Recorded operating pressures of 98.5 psi on the low side and 184.6 psi on the high side, with corresponding temperatures of 32.0°F and 58.6°F. Verified proper refrigerant charge levels and system operation on both units. Inspected condenser coils and heat exchangers for cleanliness and airflow. Documented system parameters with photographs for maintenance records. Both systems operating within normal specifications upon completion of maintenance procedures.
Completed routine cooling system maintenance on a 16-year-old air conditioning unit as part of a scheduled home plan tune-up. Inspected blower wheel assembly and found significant dust and debris accumulation on fan blades and housing, which was documented with photos; noted moisture patterns indicating condensation mixing with dust buildup. Performed standard maintenance procedures including system inspection, cleaning of components, and verification of proper operation to ensure optimal cooling performance for the season.
Completed initial service call to assess steam boiler system experiencing moisture damage to surrounding structures and adjacent piping areas. Upon inspection, observed deteriorating ceiling conditions near steam radiator unit with visible water damage, peeling paint, and plaster degradation caused by escaping steam and condensation. Documented existing copper piping configuration, radiator connections, and areas of concern including compromised wall surfaces showing moisture streaking and staining. Discussed remediation options with customer to address steam containment issues and prevent further structural damage to basement utility area.
Completed comprehensive AC tune-up on 3-year-old residential air conditioning system with rooftop condenser unit. Performed refrigerant pressure and temperature diagnostics using digital manifold gauge, recording operating pressures of 103.3 psig suction and 195 psig discharge with corresponding temperatures, confirming proper system charge and performance. System found operating within manufacturer specifications with no deficiencies noted.
Completed comprehensive AC tune-up on new cooling system. Performed standard maintenance procedures including temperature differential measurements, coil inspection, and system performance verification. All components operating within manufacturer specifications with outdoor unit showing proper refrigerant temperatures at 55°F and evaporator coil in good condition with no debris accumulation.
Completed comprehensive cooling system maintenance and tune-up on residential HVAC system. Performed thorough inspection of indoor furnace/air handler unit in basement, checking all electrical connections, blower assembly, and condensate drainage system. Evaluated outdoor condenser unit, utilizing manifold gauges to verify refrigerant pressures and system charge levels, ensuring optimal cooling performance. All components found operating within manufacturer specifications. Customer enrolled in preventive maintenance membership program during service visit.
Contacted technical support to perform diagnostic procedures on Aprilaire dehumidifier unit experiencing operational issues. Completed systematic troubleshooting protocol with manufacturer support to identify equipment malfunction and determine appropriate corrective measures. Documented equipment condition and diagnostic findings with photographic records for service documentation.
Performed comprehensive heat pump and air handler tune-up on a 20-year-old system located in a third-floor closet/crawl space. Conducted standard maintenance procedures including inspection of electrical components, measurement of system parameters with digital testing equipment showing readings of 52.5°F, and thorough evaluation of unit performance. All components were inspected and system was left in proper operating condition.
Completed HOME PLAN PLUS 2v cooling maintenance on outdoor air conditioning unit aged 10+ years. Appointment was rescheduled due to roofing work in progress at the property during original arrival time. Performed comprehensive preventive maintenance inspection and service on the cooling system per maintenance plan specifications.
Installed customer-supplied shower fixtures in bathroom with existing pink tile surround and bathtub. Replaced three-handle wall-mounted faucet assembly and tub spout with new chrome fixtures, ensuring proper connections and testing for leaks upon completion.
Responded to service call for leaking water heater at 60-year-old single-family residence. Upon inspection, diagnosed failed tank requiring complete replacement due to active leak. Removed existing deteriorated water heater and installed new Bradford White tanked unit with proper connections including copper supply lines, brass shut-off valves, temperature and pressure relief valve with discharge piping, and heat trap fittings. Completed all plumbing connections to manufacturer specifications, verified proper operation of circulator pump, ensured integration with existing water treatment system, and tested unit for leaks and proper heating function before completing service.
Responded to service call for steam boiler system at owner-occupied residence. Upon arrival and inspection, identified damaged pipe insulation on steam distribution line, which was allowing heat loss and potentially affecting system efficiency. Documented existing cast iron radiator condition and steam pipe insulation deterioration. Advised property owner of insulation repair needs to prevent continued energy loss and maintain proper steam delivery to heating zones throughout the residence.
Technician arrived on-site to address customer questions regarding a previously quoted mini split installation and to assess optimal placement locations. Interior and exterior evaluations were conducted of the proposed installation area, including review of wall structure, ceiling configuration, and exterior mounting options on the gray shingled section of the residence. Installation feasibility confirmed and placement recommendations provided to customer.
Completed routine cooling system maintenance on a 12-year-old Lennox residential air conditioning unit, model C33-36C-2-6. Performed comprehensive inspection of outdoor condenser unit, verified refrigerant lines and connections, documented equipment condition with photographs, and confirmed system operational status per manufacturer specifications.
Performed comprehensive AC tune-up on 15-year-old cooling system operating normally. Completed full system diagnostics using refrigerant manifold and micron gauge, measuring pressures, superheat, subcooling, and saturation temperatures at outdoor condenser unit. All readings confirmed proper refrigerant charge and system performance within manufacturer specifications.
Conducted on-site evaluation for mini split installation in kitchen area with potential expansion to additional zones. Assessed existing electrical panel capacity and available breaker spaces to determine power requirements for proposed ductless system. Evaluated installation location near kitchen window area and identified suitable routing paths for refrigerant lines and electrical connections. Documented current electrical infrastructure and potential mounting locations for indoor and outdoor units. Provided customer with equipment options and installation scope for single or multi-zone mini split configuration.
Completed routine seasonal air conditioning tune-up on a 13-year-old Umco cooling module system (Model MC4860CX) utilizing R-410A refrigerant. System was found operating properly with all components functioning within normal parameters; performed standard preventive maintenance procedures including inspection of electrical connections, refrigerant pressures, and overall unit operation to ensure continued reliable performance.