The Verne & Ellsworth Hann team understands the importance of functioning HVAC and plumbing systems to the health and comfort of modern life. Reliable systems are crucial, particularly in Lyndhurst, where many houses are older. Our technicians are well-versed in addressing the unique needs of these older properties, providing tailored solutions to keep them running efficiently and safely.
Contact Verne & Ellsworth Hann today for expert HVAC and plumbing services in Lyndhurst.

Comprehensive AC & Cooling Services
We offer various cooling services to keep your family comfortable during the hot Lyndhurst summer. Our team provides professional installation, replacement, repair, and maintenance services for all your cooling needs. We service a range of units, including:
- Ductless mini-splits: These systems offer flexible and efficient cooling solutions, ideal for homes without ductwork. Our technicians expertly install and maintain them to safeguard optimal performance.
- High-velocity ACs: Designed for older floorplans with limited ductwork, high-velocity AC systems deliver powerful cooling through small, flexible ducts. We guarantee precise installation and offer regular maintenance to keep your system running smoothly.
Top-Rated Heating Installation & Repair Services
Our heating services are designed to keep you warm and comfortable throughout the colder months. We offer comprehensive installation, replacement, repair, and maintenance services to meet all your heating needs. We can handle a range of systems, such as:
- Gas and electric furnaces: Our team installs, repairs, and maintains gas and electric furnaces to provide efficient and reliable heating solutions.
- Boilers: We specialize in boiler services and understand the importance of a well-functioning boiler system in older homes. Our technicians ensure your boiler operates efficiently, providing consistent warmth and comfort.
- Heat pumps: We install, repair, and maintain heat pumps, offering an energy-efficient solution for heating and cooling your residence.
Air Quality & Ductwork Services in Lyndhurst
Healthy indoor air is essential for overall well-being, and older houses sometimes struggle to maintain good air quality. Our indoor air technicians proudly provide comprehensive air quality systems and services to safeguard a healthier living environment.
- Air scrubbers and cleaners: The air scrubbers and cleaners we offer help to remove contaminants from the air, improving indoor air quality and creating a healthier home.
- Carbon monoxide detection: We install and maintain carbon monoxide detectors to protect your family from this dangerous gas.
- Whole-house humidifiers and dehumidifiers: Our technicians install and service humidifiers and dehumidifiers to maintain optimal humidity levels, enhancing comfort and preventing issues like mold growth.
Plumbing Services You Can Trust
Our team offers comprehensive plumbing services to ensure your entire system operates efficiently. From installation to repair, we cover all aspects of your plumbing needs.
- Water heaters: We install, repair, and maintain water heaters to provide your family with a reliable hot water supply.
- Water lines: Verne & Ellsworth’s technicians can install and repair water lines, ensuring a consistent and safe water supply.
- Gas lines: We offer expert installation and maintenance of gas lines, providing safe and efficient gas delivery.
- Drain snaking: Our drain snaking services effectively clear blockages and keep your plumbing system flowing smoothly.
Schedule With Verne & Ellsworth Hann in Lyndhurst
Verne & Ellsworth Hann is one of the oldest family-run businesses in Cleveland Heights. We’re known for our outstanding customer service and commitment to professionalism and integrity. Our licensed and insured technicians have been recognized with the Angi Super Service Award and Best of the Heights Award because they ensure you always receive top-quality service.
Schedule service with Verne & Ellsworth Hann today or request your free HVAC and plumbing service estimate in Lyndhurst.
Recent Jobs and Reviews in Lyndhurst, OH
Job Locations and Reviews
Completed routine maintenance on a five-year-old air conditioning system. Performed comprehensive tune-up including inspection of blower wheel and fan assembly, verified all components operating within normal parameters. System found to be in good working condition with no issues identified.
Completed preventive maintenance inspection on residential cooling system located in backyard. Performed comprehensive system evaluation including visual inspection of condensing unit components, evaporator coil assembly, and refrigerant line connections. Documented equipment condition through photographic records showing PVC condensate drain line with proper NSF-rated materials and heating element assembly within air handler cabinet, confirming all components operational and meeting manufacturer specifications.
Completed scheduled cooling maintenance on a one-year-old air conditioning system. Upon arrival, performed comprehensive inspection of outdoor condenser unit, which revealed significant accumulation of dust, dirt, and debris trapped between condenser fins and coils. Cleaned condenser coils to restore proper airflow and heat transfer efficiency, removing particulate buildup that had collected during the unit's first year of operation. Inspected refrigerant lines, electrical connections, and all accessible components in the side yard installation area. System tested and confirmed operating within normal parameters following maintenance completion.
Responded to no cooling complaint on 18-year-old air conditioning system. Performed diagnostic testing using digital multimeter to measure electrical values at outdoor unit, obtaining reading of 6.73 (volts/amps based on selector position). Inspected condenser coil condition, ductwork connections, and basement mechanical equipment installation. Completed AC tune-up service including system evaluation and necessary adjustments to restore cooling operation.
Completed scheduled cooling system maintenance visit. Performed comprehensive inspection of blower assembly and electrical components, documenting significant dust and debris accumulation on fan blades, motor housing, and electrical connections. Identified heavily soiled terminal block and wiring connectors requiring attention, with visible corrosion and contamination throughout equipment interior that could impact system efficiency and reliability.
# HVAC Maintenance - Cooling System Service
Performed comprehensive AC tune-up on residential cooling system utilizing R22 refrigerant. Connected Testo 550 digital manifold gauges to measure system pressures and temperatures, recording suction pressure of 42.5 psi and discharge pressure of 270 psi with temperatures reading 48.6°F and 50.3°F. Inspected outdoor condensing unit including condenser coil condition through protective mesh guard, verified unit was mounted properly on concrete pad.
Examined electrical connections at terminal block, noting multiple wire connections including yellow/black striped, blue, pink/red, and white wires properly secured to brass screw terminals with appropriate crimped connectors. Observed typical dust and debris accumulation on electrical components and mounting surfaces consistent with system age and operation. Inspected capacitor and associated wiring configuration for proper connections and secure mounting.
System currently operating within norma
Installed water supply line components through floor access opening, including 2 3/8" threaded angle stop valve and 1/2" compression fitting. Connected flexible braided metal supply hose to brass fittings using two 3/8" brass nipples of varying lengths (4"-6") to complete the water supply connection. All connections were secured and tested for proper operation.
Arrived on-site as scheduled for air conditioning service call. Upon arrival, documented current weather conditions showing ambient temperature of 42°F with rain, which were relevant to system evaluation. Completed visual inspection and assessment of the AC unit under these environmental conditions.
# HVAC System Installation Summary
Completed full air conditioning system installation including new outdoor condensing unit positioned on composite equipment pad with proper gravel base for drainage and stability. Installed new evaporator coil integrated with existing air handler system, with refrigerant lines properly connected and insulated. Established refrigerant charge using manifold gauges and verified system pressures met manufacturer specifications. Installed new electrical disconnect box for outdoor unit with appropriate wire sizing and circuit protection. Mounted new programmable thermostat for enhanced temperature control and system efficiency. All refrigerant connections secured with brass fittings and proper torque specifications. PVC condensate drainage lines configured with appropriate pitch and trap installation. System tested for proper operation including compressor function, airflow verification, and temperature differential measurements. All electrical connections
Responded to emergency plumbing call for multiple failed shutoff valves in 1955-era home. Upon arrival, assessed three compression-type shutoff valves with active leaks: one serving downstairs toilet, one at bathroom sink supply line, and one completely broken off at the supply line connection. Previous attempted repairs by occupant had exacerbated damage to valve stems and compression fittings.
Shut off main water supply to prevent further water intrusion. Documented extensive water damage to subfloor plywood beneath fixtures, showing significant staining and moisture penetration. Removed all three failed compression valves and assessed supply line conditions. The valve that had broken off required additional attention to remove remaining components from the supply line without damaging copper piping.
Installed three new quarter-turn ball valves with appropriate compression fittings to replace failed units. Verified proper shutoff function on all new valves. Restored water supply a
Conducted on-site assessment for mini split installation in upper-floor attic space. Identified existing knob and tube wiring in the area, which presents electrical compatibility concerns that require further evaluation before proceeding with installation. Documented room conditions and existing electrical infrastructure through photographs for review and determination of necessary electrical upgrades to support the mini split system.
Performed comprehensive AC tune-up on residential split system with outdoor condensing unit and indoor air handler. System evaluated and found operating within normal parameters at time of service. Documented equipment condition through photographic inspection of outdoor unit installation on concrete pad with proper clearances and indoor mechanical components in basement utility area.
Responded to service call for 50-gallon gas water heater leaking from bottom of tank. Upon inspection, determined tank failure required complete unit replacement. Successfully removed failed water heater and installed new 50-gallon gas unit with proper copper piping connections, ensuring all plumbing code requirements were met and system restored to full operational status.
Performed annual maintenance on 20-year-old Slant/Fin boiler system. Removed front access panel to inspect internal components including burner assembly, heat exchanger, gas valve, and control board. Verified all electrical connections, wire bundles, and control circuits were secure and functioning properly. Conducted combustion analysis using digital diagnostic meter, recording stack temperature of 482°F and ambient temperature readings. All measured parameters including CO and CO2 levels were within acceptable operating ranges. Inspected gas piping, connections, and safety controls for proper operation. System tested and returned to normal service with all components operating as designed.
Performed routine preventative maintenance on an 11-year-old Carrier air conditioning system. Unit was inspected, cleaned, and tested to ensure optimal cooling performance for the upcoming season. All components were found to be operating within normal parameters, and the system is ready for continued service.
Completed full HVAC system replacement including removal of existing furnace, evaporator coil, condenser unit, and water heater. Installed new Bryant furnace and coil downsized to 17" width to optimize utility closet space constraints. Replaced supply plenum to improve airflow efficiency throughout the system. Installed new Ecobee thermostat with model 1410 control system for enhanced climate management. Replaced water heater with reduced diameter unit (18" vs. previous 20") and repositioned equipment around existing chimney structure to accommodate proper clearances. Relocated furnace and return air drop to right side of closet to ensure door clearance and accessibility. All PVC venting, copper water lines, and electrical connections completed to code. System tested and operational upon completion.
Responded to no-heat call on 2-year-old furnace system. Upon arrival, performed diagnostic inspection of unit and identified failed dual run capacitor as cause of system failure. Capacitor showed signs of deterioration with visible discoloration and tested outside acceptable microfarad range. Replaced defective capacitor with OEM-specification component, verified all electrical connections, and tested system operation through complete heating cycle. Unit restored to full operational status with proper ignition sequence, blower motor function, and heat output. Confirmed warranty coverage applies to failed component.
# HVAC Maintenance - Heating System Service Summary
Completed comprehensive furnace and humidifier tune-up as part of scheduled preventive maintenance. Performed diagnostic testing using digital multimeter to verify electrical performance and system operation, with all readings within manufacturer specifications. System inspected, serviced, and confirmed operational for the heating season.
Performed routine maintenance on 10-year-old gas furnace (model 8-12) as requested. Inspected burner assembly which showed proper blue flame pattern indicating complete combustion. Checked gas valve operation, electrical connections, and control wiring - all components functioning within normal parameters.
Responded to service call for 16-year-old gas furnace with short cycling issues. Upon inspection, found unit would ignite but shut off prematurely. Confirmed system does produce heat when operational. Diagnosed issue as unrelated to previous service call from 3/12. Removed access panel for thorough component inspection and documented system condition with photos.