Superior heating and cooling in Cleveland’s eastern suburbs
As a family-run company that has been a fixture of Northeast Ohio for over 70 years, Verne & Ellsworth Hann is proud to serve both residents and business owners in Richmond Heights. The team at Verne & Ellsworth Hann is exceptionally knowledgeable about all things HVAC, heating, cooling, plumbing, and air quality. Whether repairing a boiler, installing a state-of-the-art furnace, or tuning up an air conditioning unit, Verne & Ellsworth Hann has the most extensive experience in Richmond Heights; we offer comprehensive installation, maintenance, and repair of the following:
- Furnaces
- Boilers
- Radiators
- Air conditioners
- Whole-home generators
- Hot water tanks
- Toilets
- Faucets
- Garbage disposals
- Gas piping
- Water lines
- Air cleaners and purifiers
- Humidifiers and dehumidifiers
- Carbon monoxide detectors
- And much more!
Are you a home owner in Richmond Heights who is in need of affordable, high-quality heating and cooling expertise? Look no further! Contact Verne & Ellsworth Hann today to schedule a free, no-obligation consultation and estimate. Our experienced professionals are standing by.
Verne and Ellsworth Hann has completed 20 jobs in Richmond Heights, OH between March 2026 and September 2026. The most recent job was on September 17, 2026.Recent Jobs and Reviews in Richmond Heights, OH
Richmond Heights, OH at a glance
Job Locations and Reviews
Conducted furnace and air conditioning replacement estimate for residential HVAC system over 16 years old. Evaluated existing Carrier equipment and ductwork configuration in basement utility area, documented current system condition through photographs, and discussed available replacement options including current promotional offerings with homeowner.
Completed full HVAC system replacement including removal of existing equipment and installation of new Bryant furnace, evaporator coil, and outdoor condensing unit. Installed new furnace in basement mechanical room with proper venting through existing exhaust duct penetration. Mounted evaporator coil on top of furnace plenum and connected refrigerant lines to outdoor condenser. Verified all electrical connections to furnace control board and condensing unit per manufacturer specifications. Performed system startup procedures and confirmed proper airflow by measuring static pressure at 150 pascals using digital manometer. Tested heating and cooling cycles to ensure equipment operates within normal parameters. Customer was informed that existing thermostat may not be compatible with new system but will attempt programming if possible.
Completed scheduled heating maintenance tune-up on 3-year-old Carrier furnace system. Performed comprehensive inspection of all internal components including blower motor assembly, electrical connections, gas valve, heat exchanger, venting system, and control wiring. Verified proper operation of ignition system, flame sensor, and all safety controls. No issues or deficiencies identified during inspection; system operating within manufacturer specifications.
Conducted furnace replacement estimate in basement mechanical room. Inspected existing vertically-oriented furnace unit with open access panel, evaluating internal components including burners, blower assembly, wiring, valves, and mechanical connections. Assessed condition of gray metal ductwork extending from unit and connecting supply/return air distribution system. Documented equipment specifications from manufacturer labels and data plates. Photographed installation location, existing ductwork configuration, electrical connections, and overall mechanical room layout to prepare comprehensive replacement proposal.
Responded to no cooling complaint on residential air conditioning system over 10 years old. Upon arrival, performed diagnostic inspection of outdoor condensing unit and found system inoperative due to age-related component failure and deteriorated electrical connections beneath unit platform, which showed significant weather damage and corrosion to mounting hardware and wiring conduits.
Responded to service call for two separate faucet issues. Replaced worn cartridge in bathroom faucet to resolve active leak. Repaired leaking hot water valve on garage faucet, addressing shut-off valve malfunction at washing machine supply connections. Both fixtures tested and verified operational with no further leakage upon completion.
Installed wireless thermostat system in suitable location for optimal climate control. Successfully mounted PRO wireless access system receiver unit and completed all necessary wiring connections to integrate with existing HVAC infrastructure in basement mechanical area.
Completed scheduled cooling maintenance visit on residential air conditioning system. Performed comprehensive system diagnostics using digital manifold gauges, measuring refrigerant pressures and temperatures to verify proper operation. System readings showed 103.7 PSI low side pressure, 199.6 PSI high side pressure, with temperatures of 130°F and 110.8°F, indicating normal operating parameters for R-410A refrigerant. All measurements confirmed system is functioning within manufacturer specifications.
Performed preventative maintenance on a 6-year-old Carrier/BDP condensing unit, model CNPVP36017ALAAAAA, utilizing R-410A refrigerant. Measured and recorded system pressures and temperatures using digital manifold gauges, confirming proper operating conditions and refrigerant charge levels. Inspected condenser coil fins, manufacturer labels, and safety documentation, verifying all components were functioning within normal parameters.
Completed A/C system startup and addressed exterior penetration sealing as identified during inspection. Properly caulked and sealed the wall penetration where refrigerant line set passes through vinyl siding to prevent air and moisture infiltration, ensuring code compliance and system protection.
Completed comprehensive Home Plan cooling tune-up maintenance on two HVAC systems. Performed standard preventive maintenance procedures including system diagnostics, airflow measurements using digital manometer registering 15.3 inches of water column static pressure, and electrical testing with multimeter to verify proper voltage and amperage readings. All systems operational and running within manufacturer specifications upon completion.
Completed full HVAC system replacement including installation of new two-stage high-efficiency furnace elevated on platform box and two-stage air conditioner with outdoor condenser unit mounted on rubber pad. Installed new AprilAire 4-inch media filter (20x25x4), ran refrigerant lines through foundation, mounted electrical disconnect box, routed PVC condensate drain line along exterior wall, and installed new programmable digital thermostat.
Performed comprehensive evaluation of aging 20+ year old heat pump system during scheduled maintenance appointment. Upon inspection, documented existing HVAC equipment configuration including gray metal furnace/air handler unit with integrated white humidifier assembly, PVC condensate drainage piping, and associated ductwork plenum. System assessment revealed equipment had exceeded its effective service life, prompting recommendation for complete system replacement. Captured detailed photographic documentation of current installation showing furnace unit with manufacturer specification labels, white PVC drain lines with mounting brackets, black electrical conduit, copper refrigerant tubing, and concrete floor installation area. Provided estimate for full HVAC system replacement to address reliability concerns and improve energy efficiency for residential heating and cooling needs.
Performed routine maintenance inspection on residential air conditioning system. Unit was accessed on side of house, with outdoor condenser positioned on concrete pad in good condition. Connected manifold gauges to verify refrigerant pressures and system performance. All refrigerant lines showed proper insulation with no visible damage or wear. Condenser coils were clean with adequate airflow through vertical fins. Fan guard and motor assembly operating normally. System tested under fair weather conditions at 59°F ambient temperature, confirming proper operation ahead of cooling season. No repairs required at this time.
# HVAC Maintenance - Cooling System Service
Performed comprehensive preventive maintenance on a 20+ year old heat pump system during first service call. Upon inspection, unit showed significant age-related deterioration including heavy rust and corrosion on interior metal components and panels, with visible mineral deposits and efflorescence indicating previous moisture exposure. Blower motor assembly and electrical connections were inspected and found operational despite equipment age. Cleaned accumulated dust, debris, and cobwebs from interior compartments. Verified proper electrical connections at motor terminals and control components. Assessed refrigerant line routing and condition. System operational at time of departure, though advanced age and corrosion levels noted for customer awareness regarding future equipment considerations.
Completed comprehensive preventive maintenance on both air conditioning and furnace systems. Performed standard tune-up procedures including refrigerant pressure testing using manifold gauges on the outdoor condenser unit, verified proper refrigerant levels for R-410A system, inspected condenser fan operation and housing integrity, and conducted thorough system diagnostics. All equipment operating within normal parameters with no deficiencies noted.
Responded to a service call for a 14-year-old natural gas steam boiler with a reported leak at the sight glass assembly. Upon arrival, confirmed the unit had been shut down by the customer as a safety precaution. Inspected the sight glass assembly, associated piping connections, and shut-off valves, documenting the condition with photographs for service records and future reference.
Completed comprehensive air conditioning maintenance tune-up on residential cooling system. Performed thorough inspection of indoor air handler unit, including blower assembly, motor housing, and refrigerant line connections. Documented equipment specifications and current system condition with photographs. Noted moderate dust and debris accumulation on exterior condenser unit and surrounding area, with visible leaf debris and surface corrosion on refrigerant line connections. All mechanical components operating within normal parameters at time of service. System confirmed to be functioning properly upon completion of preventive maintenance procedures.
Responded to service call for thermostat error code on furnace installed last August. Performed comprehensive furnace tune-up including inspection of burner assembly, blower wheel, and all operational components. Verified proper combustion with blue flame pattern across burner assembly, inspected blower wheel for dust accumulation and wear, and checked all electrical connections and wiring harnesses. Completed humidifier tune-up as part of preventative maintenance service. Reset service reminder and documented system operation with photographic records showing burner operation and internal components functioning properly.
Successfully installed Nu-Shield air purification system within HVAC unit. Accessed internal components, connected wiring to main control board, and verified proper integration with existing system. Final inspection confirmed system functioning correctly with all connections secure.