Verne & Ellsworth Hann is renowned for outstanding HVAC and plumbing services! Being in business since 1907 makes us one of the oldest family-run companies in Cleveland Heights, OH. We offer the finest heating, air conditioning, plumbing, and boiler services to residents of Cleveland Heights.
To schedule top HVAC and plumbing services in Cleveland Heights, OH, call Verne & Ellsworth Hann at (216) 932-9755!

Dependable Heating & Cooling Services
Verne & Ellsworth Hann’s exceptional technicians can install, replace, repair, and maintain your heating or cooling system in Cleveland Heights, OH. You get consistently prompt, respectful service, no matter what type of issue you have.
We offer services for:
- Ductless mini-splits: This cost-effective, energy-efficient method of heating and cooling can be set for specific areas of your home, called zones, instead of having your whole house at one temperature.Â
- Heat pumps: A heat pump heats and cools your home. It’s environmentally safe, inconspicuous, and saves money. Our technicians and technology keep your heat pump working.
- Furnaces: Verne & Ellsworth Hann keeps your home warm in Cleveland Heights, OH! Our installation, repair, and maintenance services ensure your gas or electric furnace runs throughout the coldest Ohio winters.
- Boilers: We are the boiler specialists you want when your boiler requires installation, repair, or replacement. When you experience thermostat issues, system leaks, or lack of heat, turn to Verne & Ellsworth Hann!
- Packaged units: These combine heating and cooling components into a single, convenient unit, conserving space. If your packaged unit in Cleveland Heights, OH, needs to be installed, replaced, repaired, or maintained, Verne & Ellsworth Hann will do it!
Air Quality & Ductwork Services in Cleveland Heights
Excellent indoor air quality helps maintain good health. Verne & Ellsworth Hann’s indoor air quality solutions feature up-to-date technology so the air in your Cleveland Heights, OH, home is as pure as possible.
We handle installation, replacement, repair, and maintenance for:
- Air scrubbers: An air scrubber eliminates dust, pollutants, odors, and other unwanted particles from the air. It can be connected to your ductwork.
- Air purifiers: We provide state-of-the-art technology, like using UV light, to keep your air free of odors, particulates, germs, and mold.
- Whole-house humidifiers: Arid air causes issues with your eyes, mouth, nose, and lips. A whole-house humidifier maintains an ideal comfort level all the time.
Let Verne & Ellsworth Hann improve the indoor air quality of your Northeast Ohio home. Contact our team at (216) 932-9755!
Exceptional Plumbing Services
Since 1952, Verne & Ellsworth Hann has provided first-class plumbing services in Cleveland Heights, OH, addressing:
- Water heaters: We install, replace, and repair tankless, gas, and electric water heaters.
- Water lines: When there are soggy areas in your yard or your tap water is discolored, call us for water line installation, replacement, or repair!
- Gas lines: Problems with your gas line are dangerous. Exit your home immediately, contact your utility company, and let us pinpoint the issue and restore your peace of mind.
- Bathroom & kitchen plumbing: Don’t put up with a broken faucet, malfunctioning garbage disposal, or overflowing toilet! We’ll find the problem fast and correct it.
Verne & Ellsworth Hann is your source for outstanding plumbing services in Cleveland Heights, OH! Call (216) 932-9755 to schedule services today!
Choose Verne & Ellsworth Hann in Cleveland Heights, OH
You can trust Verne & Ellsworth Hann as your HVAC and plumbing partner in Northeast Ohio, including Cleveland Heights. We believe in professionalism, integrity, and transparency. Our licensed and insured techs uphold those standards and are happy to serve you!
We earned the Angi Super Service Award and Best of the Heights Award because of our knowledge, responsiveness, and dedication to satisfying each customer.
Call Verne & Ellsworth Hann at (216) 932-9755 to schedule HVAC or plumbing services in Cleveland Heights, OH, today!
Recent Jobs and Reviews in Cleveland Heights, OH
Job Locations and Reviews
Completed preventive maintenance tune-up on two residential air conditioning systems: a 15-year-old unit and a 10-year-old unit, with one located in the basement and one positioned outside. Performed comprehensive inspection of both systems including blower motor assemblies, examined electrical connections and wiring, verified proper motor operation, and assessed cooling fan components which showed normal dust accumulation consistent with equipment age and use. Both systems found to be in operational condition following standard maintenance procedures.
Performed comprehensive air conditioning tune-up on approximately 20-year-old outdoor unit. Conducted system diagnostics and measurements using digital testing equipment, verified operational parameters, and completed preventive maintenance procedures to ensure proper cooling performance.
Responded to service call for clogged sink drain and low hot water pressure. Upon inspection, discovered significant mineral buildup and sediment accumulation in plumbing fixtures. Cleared blockage from sink drain line using appropriate drain cleaning equipment. Identified corroded internal tank components and discolored water indicating mineral deposits affecting water flow. Addressed hot water pressure issue by flushing sediment from supply lines and inspecting aerators. Restored proper drainage to sink and improved hot water pressure to normal operating levels.
Responded to boiler repair call for 10-year-old unit at owner-occupied residence. Upon arrival, inspected boiler control system and accessed main electrical enclosure containing dual circuit boards with LED indicators and multi-colored wiring harnesses. Evaluated control board functionality, verified proper electrical connections at terminal strips, and confirmed all indicator lights were operational. System tested and returned to normal operation with no component replacements required at this time.
Responded to no-heat call for 20-year-old furnace. Upon arrival, performed diagnostic inspection and found unit was not igniting. Checked electrical connections, gas supply, and ignition system components including flame sensor and burner assembly. Cleaned flame sensor rod and verified proper positioning over burner ports. Cycled unit and confirmed successful ignition with proper blue flame pattern across all burners. Verified all safety controls functioning correctly and unit operating within normal parameters. System restored to full heating operation.
Responded to water leak in basement of 106-year-old residential property. Upon arrival, located source of leak in crawl space beneath main floor. Inspection revealed severely corroded galvanized steel supply piping with extensive rust deterioration at multiple joints and valve connections. Primary leak originated from compromised vertical pipe section where corrosion had penetrated through pipe wall at coupling assembly.
Shut off main water supply to prevent further water damage. Removed failed corroded pipe section and associated fittings exhibiting structural compromise from rust buildup and mineral deposits. Cut out approximately four feet of deteriorated galvanized piping. Installed new copper pipe section with compression fittings and brass shutoff valve to replace corroded assembly. Secured new piping to floor joists with appropriate hangers and supports.
Tested system for leaks by restoring water pressure and monitoring all connections for twenty minutes. Verified no active le
Performed preventative maintenance on two residential cooling systems: one outdoor condenser unit located in the backyard and one air handler unit installed in the attic space. Conducted temperature diagnostics on the outdoor unit, recording surface temperature readings of 54.5°F on the condenser pad. Inspected condenser coil fins, concrete pad condition, and overall exterior unit operation. In the attic, evaluated the air handler system including flexible ductwork connections, insulated refrigerant line sets, PVC condensate drainage system, and auxiliary condensate pump assembly. Verified proper installation of all components, checked insulation integrity on refrigerant lines, and confirmed condensate removal systems were functioning correctly. Both systems appeared operational with all major components accessible for routine service.
Responded to emergency call for frozen anti-frost spigot installed the previous year with suspected burst pipes. Upon arrival, inspected exterior spigot mounted on brick wall and accessed crawl space to evaluate copper supply line condition. Found compromised pipe insulation and deteriorated vapor barrier mesh in underfloor area. Assessed brass fittings and copper piping for freeze damage, verified structural integrity of plumbing connections, and documented conditions of both exterior spigot installation point and interior supply line routing through floor joists.
Responded to no heat call on an eight-year-old furnace. Upon arrival, performed diagnostic testing using digital multimeter to check electrical components and thermocouple voltage readings, which measured 0.18V indicating a failed thermocouple. Replaced faulty thermocouple assembly, restored proper millivolt signal to gas valve, and verified furnace ignition sequence and heating operation throughout the home.
Completed professional installation of customer-supplied kitchen sink in granite countertop over a two-day service period. Installation included mounting stainless steel double-basin sink, installing modern single-handle pull-down faucet with brushed metal finish, and configuring complete under-sink plumbing assembly with garbage disposal unit, PVC P-trap drainage system, copper water supply lines, and shut-off valves. All components tested and verified operational upon completion.
Completed annual preventive maintenance on one-year-old air conditioning system. Performed comprehensive system diagnostics using refrigerant manifold gauges to measure operating pressures, temperatures, superheat, and subcooling values, confirming all parameters within manufacturer specifications for optimal cooling performance.
Completed comprehensive maintenance on 22-year-old air conditioning system and 21-year-old gas furnace. Performed full system inspection including evaporator coil cleaning, condenser coil assessment, refrigerant line inspection, and blower motor evaluation in response to customer concerns about potential blower issues. All components photographed and documented, with particular attention to coil condition and refrigerant connections showing age-appropriate wear on copper lines and insulation.
Responded to service call for multiple plumbing fixtures requiring repair. Addressed dripping faucets throughout the property, including the wall-mounted three-piece bathroom faucet assembly with dual lever handles and center spout. Diagnosed and corrected shower temperature fluctuation issue caused by pressure imbalance in the mixing valve. Repaired continuously running toilet by replacing faulty flapper valve and adjusting fill valve mechanism to restore proper water shutoff function.
Completed comprehensive AC tune-up on 10-year-old residential air conditioning system. Performed full system inspection of indoor air handler and outdoor condensing unit, verified refrigerant pressures and temperatures using digital manifold gauges with readings showing 94.7 PSIG suction pressure with 24°F superheat and 204.9 PSIG discharge pressure at 118°F, indicating proper refrigerant charge and system operation. Inspected condenser coil condition, checked electrical connections, and confirmed all components functioning within manufacturer specifications. System operating efficiently with no issues identified or repairs required at time of service.
Completed routine cooling system maintenance on a 12-year-old air conditioning unit, including comprehensive inspection of the blower motor assembly and verification of refrigerant pressures and system temperatures. All measured values were within manufacturer specifications, with operating pressures of 906 PSIG on the high side and 271.0 PSIG on the low side, confirming proper system charge and performance for continued efficient operation.
Completed comprehensive AC tune-up on 9-year-old residential cooling system. Performed standard maintenance protocol including refrigerant pressure and temperature diagnostics using digital manifold gauges, confirming system operating within manufacturer specifications at 95.2 PSI suction and proper superheat/subcooling values. Inspected condenser unit exterior components, coil condition, and refrigerant lines for wear or damage. System found to be operating efficiently with no deficiencies noted at time of service.
Conducted follow-up site assessment for mini split installation estimate in residential bedroom. Documented room layout, existing heating infrastructure including baseboard radiator, ceiling configuration with drop tile panels, and electrical conduit routing. Evaluated optimal placement locations for indoor air handler unit and assessed wall penetration requirements for refrigerant line set routing to exterior condensing unit.
Completed annual preventative maintenance on a 3-year-old Carrier air conditioning system utilizing R-410A refrigerant. Performed comprehensive system inspection including visual examination of indoor air handler unit, verified manufacturer specifications and equipment labeling integrity. Conducted refrigerant system diagnostics using Fieldpiece SMAN manifold gauge, measuring operating pressures at 110.5 PSI suction and 110.8 PSI discharge, with superheat reading of 53.1°F and subcool at 5.18°F. All system parameters found within normal operating range. Unit operating efficiently with no deficiencies noted. System ready for continued service through cooling season.
Completed scheduled recurring cooling system maintenance on a 7-year-old unit. Appointment was rescheduled at customer's request and performed as first call of the day. Inspected refrigerant lines in mechanical room, which were found to be properly secured and in good condition with no visible signs of wear or leakage.
Performed seasonal tune-up on Bryant mini split air conditioning system that was installed last year but had not yet been operated this season. Conducted comprehensive inspection of both indoor and outdoor units, verified refrigerant levels, cleaned filters, checked electrical connections, and tested system operation to ensure proper functionality for the cooling season. All components found to be in good working condition with no issues identified.