HVAC & Plumbing Services in Shaker Heights

With five generations of knowledge, Verne & Ellsworth Hann has provided our clients in Shaker Heights with outstanding customer service. When you need trained HVAC technicians or certified plumbing services, you can count on Verne & Ellsworth.

Northeast Ohio’s Heating, Air Conditioning, Boilers, Plumbing experts. If you’re having problems with your HVAC or plumbing, contact us today!

Verne & Ellsworth Hann technician installing a new thermostat in an Ohio home

Reliable Heating Replacement & Repair

The average winter temperature for Shaker Heights is 36 degrees. When the weather is that cold, you need to know you can count on your heating unit to do its job. Inevitably, heating units will break down, but you can always count on Verne & Ellsworth for reliable heating services. We can install, replace, repair, and maintain your home’s heating unit. 

Our qualified heating technicians have decades of experience with:

  • Gas and electric furnaces: These are tried and tested methods for keeping your home warm. With reliable fuel sources and the ability to share your AC’s existing ductwork, a furnace is a fantastic option for heating your home.
  • Boilers: Boilers heat the home by boiling water, piped throughout to radiate heat into the air. This centuries-old device uses one of the most reliable methods around.
  • Heat pumps: Heat pumps are a modern way to heat your home. They work without external heat sources, such as furnaces and boilers, and can pull heat from the air, ground, or a nearby water source. 

Comprehensive Cooling & AC Services

When the humidity spikes and the temperature approaches 90 degrees, it’s no time for your AC to stop. No matter the issue, you can count on Verne & Ellsworth for trustworthy cooling services. Our certified AC technicians can install, replace, repair, and maintain your home’s AC unit.

We have decades of knowledge in:

  • Ductless mini-splits: A ductless mini-split gives you complete control over your home’s temperature without the cumbersome ductwork of traditional units. A ductless mini-split cools your home through an individual unit mounted to the wall in each room.
  • High-velocity ACs: High-velocity AC units are a perfect option for historic homes in the Shaker Heights area. Instead of ductwork, they use small, flexible tubing to pipe air throughout your home.

Air Quality & Ductwork Services in Shaker Heights

The air quality in your home has a significant impact on your health and well-being. This is why Verne & Ellsworth is proud to work with units such as:

Top-Rated Plumbing Services

Malfunctioning plumbing is a fast way to ruin your day. You can count on Verne & Ellsworth when you need qualified plumbing services. We’ll keep your plumbing running smoothly with such services as:

  • Water heaters: We can install or repair your traditional or tankless water heaters.
  • Water lines: We can install or repair your water lines to keep your potable water flowing. 
  • Gas lines: We can pipe, repair, and test your gas lines to ensure your home’s safety.
  • Drain snaking: We’ll keep your home draining smoothly, removing any pesky clogs you may face.

Schedule With Verne & Ellsworth Hann in Shaker Heights

One of the oldest family-run businesses in the area, Verne & Ellsworth has won the Angi Super Service Award and the Best of the Heights Award. We are committed to outstanding customer service, professionalism, and integrity. When our licensed and insured technicians set foot on your property, you can rest assured the job will be done right.

Contact our team today to request a free estimate or to schedule services in Shaker Heights.

Recent Jobs and Reviews in Shaker Heights, OH

Job Locations and Reviews

Completed preventive maintenance on two residential air conditioning systems: a 2-year-old outdoor condensing unit and a 6-year-old attic-mounted air handler. Performed comprehensive inspections including checking refrigerant levels, cleaning condenser coils, verifying electrical connections, testing capacitors, inspecting drain lines, replacing air filters, and confirming proper airflow and temperature differentials on both systems. All equipment operating within manufacturer specifications with no deficiencies noted.
Completed preventive maintenance on two residential air conditioning systems: a 2-year-old outdoor condensing unit and a 6-year-old attic-mounted air handler. Performed comprehensive inspections including checking refrigerant levels, cleaning condenser coils, verifying electrical connections, testing capacitors, inspecting drain lines, replacing air filters, and confirming proper airflow and temperature differentials on both systems. All equipment operating within manufacturer specifications with no deficiencies noted.
VH L.
VH L. Checked in
Completed preventive maintenance on two residential air conditioning systems: a 2-year-old outdoor condensing unit and a 6-year-old attic-mounted air handler. Performed comprehensive inspections including checking refrigerant levels, cleaning condenser coils, verifying electrical connections, testing capacitors, inspecting drain lines, replacing air filters, and confirming proper airflow and temperature differentials on both systems. All equipment operating within manufacturer specifications with no deficiencies noted.
Shaker Heights, OH 44120
Responded to no cooling complaint on 16-year-old air conditioning system. Performed comprehensive system evaluation of attic-mounted air handler unit and associated components. Documented existing equipment configuration including air handler, ductwork connections, refrigerant line routing, and electrical connections. Provided replacement estimate for complete HVAC system due to age and failure of existing equipment.
Responded to no cooling complaint on 16-year-old air conditioning system. Performed comprehensive system evaluation of attic-mounted air handler unit and associated components. Documented existing equipment configuration including air handler, ductwork connections, refrigerant line routing, and electrical connections. Provided replacement estimate for complete HVAC system due to age and failure of existing equipment.
VH S.
VH S. Checked in
Responded to no cooling complaint on 16-year-old air conditioning system. Performed comprehensive system evaluation of attic-mounted air handler unit and associated components. Documented existing equipment configuration including air handler, ductwork connections, refrigerant line routing, and electrical connections. Provided replacement estimate for complete HVAC system due to age and failure of existing equipment.
Shaker Heights, OH 44122
Completed comprehensive AC tune-up service on residential air conditioning system with no reported issues. Performed standard preventive maintenance procedures including temperature diagnostics on outdoor condenser unit, recording discharge temperature of 138°F, and inspection of return air grille which showed moderate dust and debris accumulation along slats and frame edges. All system components checked and unit operating within normal parameters.
Completed comprehensive AC tune-up service on residential air conditioning system with no reported issues. Performed standard preventive maintenance procedures including temperature diagnostics on outdoor condenser unit, recording discharge temperature of 138°F, and inspection of return air grille which showed moderate dust and debris accumulation along slats and frame edges. All system components checked and unit operating within normal parameters.
VH U.
VH U. Checked in
Completed comprehensive AC tune-up service on residential air conditioning system with no reported issues. Performed standard preventive maintenance procedures including temperature diagnostics on outdoor condenser unit, recording discharge temperature of 138°F, and inspection of return air grille which showed moderate dust and debris accumulation along slats and frame edges. All system components checked and unit operating within normal parameters.
Shaker Heights, OH 44120
Responded to service call for three-year-old mini split air conditioning system not cooling properly. Upon arrival, performed diagnostic inspection of both indoor and outdoor units. Inspected refrigerant line set, condensate drainage system, and electrical connections visible at exterior installation. Verified proper operation of condensate drain line and checked for any visible obstructions or damage to refrigerant lines running along building exterior. Evaluated outdoor unit mounting and line set routing for any potential issues affecting system performance. Documented equipment condition with photographs showing exterior components including line set installation, utility disconnect box, and condensate drain configuration.
Responded to service call for three-year-old mini split air conditioning system not cooling properly. Upon arrival, performed diagnostic inspection of both indoor and outdoor units. Inspected refrigerant line set, condensate drainage system, and electrical connections visible at exterior installation. Verified proper operation of condensate drain line and checked for any visible obstructions or damage to refrigerant lines running along building exterior. Evaluated outdoor unit mounting and line set routing for any potential issues affecting system performance. Documented equipment condition with photographs showing exterior components including line set installation, utility disconnect box, and condensate drain configuration.
VH-Paul K.
VH-Paul K. Checked in
Responded to service call for three-year-old mini split air conditioning system not cooling properly. Upon arrival, performed diagnostic inspection of both indoor and outdoor units. Inspected refrigerant line set, condensate drainage system, and electrical connections visible at exterior installation. Verified proper operation of condensate drain line and checked for any visible obstructions or damage to refrigerant lines running along building exterior. Evaluated outdoor unit mounting and line set routing for any potential issues affecting system performance. Documented equipment condition with photographs showing exterior components including line set installation, utility disconnect box, and condensate drain configuration.
Shaker Heights, OH 44120
Shaker Heights, OH - Performed follow-up service call to address loose handles on recently installed three-piece bathroom faucet assembly mounted on granite countertop. Tightened mounting hardware and verified proper installation of single-handle chrome faucet to ensure secure operation and eliminate movement at base connections.
Joseph M.
Joseph M. Checked in
Performed follow-up service call to address loose handles on recently installed three-piece bathroom faucet assembly mounted on granite countertop. Tightened mounting hardware and verified proper installation of single-handle chrome faucet to ensure secure operation and eliminate movement at base connections.
Shaker Heights, OH 44120
Responded to no cooling complaint on two separate air conditioning units. Upon inspection, identified broken refrigerant line on first unit requiring repair. Diagnosed electrical issue on second unit and performed necessary troubleshooting and repairs to restore both systems to proper operation.
Responded to no cooling complaint on two separate air conditioning units. Upon inspection, identified broken refrigerant line on first unit requiring repair. Diagnosed electrical issue on second unit and performed necessary troubleshooting and repairs to restore both systems to proper operation.
VH L.
VH L. Checked in
Responded to no cooling complaint on two separate air conditioning units. Upon inspection, identified broken refrigerant line on first unit requiring repair. Diagnosed electrical issue on second unit and performed necessary troubleshooting and repairs to restore both systems to proper operation.
Shaker Heights, OH 44122
Completed preventive maintenance on two air conditioning units over 3 years old as part of MVP program. Performed comprehensive system inspections including refrigerant pressure and temperature measurements using digital manifold gauges, verified proper operating pressures at 51.1 PSI with superheat readings, and confirmed system performance parameters were within manufacturer specifications for both units.
Completed preventive maintenance on two air conditioning units over 3 years old as part of MVP program. Performed comprehensive system inspections including refrigerant pressure and temperature measurements using digital manifold gauges, verified proper operating pressures at 51.1 PSI with superheat readings, and confirmed system performance parameters were within manufacturer specifications for both units.
VH P.
VH P. Checked in
Completed preventive maintenance on two air conditioning units over 3 years old as part of MVP program. Performed comprehensive system inspections including refrigerant pressure and temperature measurements using digital manifold gauges, verified proper operating pressures at 51.1 PSI with superheat readings, and confirmed system performance parameters were within manufacturer specifications for both units.
Shaker Heights, OH 44122
Performed comprehensive seasonal AC tune-up and system diagnostics on residential cooling system that had been dormant since previous summer. Conducted thorough visual inspection of outdoor condensing unit, indoor evaporator coil, and all associated components. Utilized Testo 550 digital manifold gauge to measure and record system operating pressures and temperatures, confirming refrigerant charge levels and system performance parameters. Suction pressure reading of 15.5 psig with corresponding temperature of 13.3°F and high-side pressure of 50.2 psig indicated proper refrigerant charge and system operation. Inspected condenser coil fins for damage or blockage, verified electrical connections at unit, and checked capacitor values. Cleaned condenser coil to ensure optimal heat transfer efficiency. Verified proper compressor amperage draw and operation. Inspected and tested contactor operation and relay functionality. Checked refrigerant line insulation for deterioration. Confirmed prope
Performed comprehensive seasonal AC tune-up and system diagnostics on residential cooling system that had been dormant since previous summer. Conducted thorough visual inspection of outdoor condensing unit, indoor evaporator coil, and all associated components. Utilized Testo 550 digital manifold gauge to measure and record system operating pressures and temperatures, confirming refrigerant charge levels and system performance parameters. Suction pressure reading of 15.5 psig with corresponding temperature of 13.3°F and high-side pressure of 50.2 psig indicated proper refrigerant charge and system operation. Inspected condenser coil fins for damage or blockage, verified electrical connections at unit, and checked capacitor values. Cleaned condenser coil to ensure optimal heat transfer efficiency. Verified proper compressor amperage draw and operation. Inspected and tested contactor operation and relay functionality. Checked refrigerant line insulation for deterioration. Confirmed prope
VH P.
VH P. Checked in
Performed comprehensive seasonal AC tune-up and system diagnostics on residential cooling system that had been dormant since previous summer. Conducted thorough visual inspection of outdoor condensing unit, indoor evaporator coil, and all associated components. Utilized Testo 550 digital manifold gauge to measure and record system operating pressures and temperatures, confirming refrigerant charge levels and system performance parameters. Suction pressure reading of 15.5 psig with corresponding temperature of 13.3°F and high-side pressure of 50.2 psig indicated proper refrigerant charge and system operation. Inspected condenser coil fins for damage or blockage, verified electrical connections at unit, and checked capacitor values. Cleaned condenser coil to ensure optimal heat transfer efficiency. Verified proper compressor amperage draw and operation. Inspected and tested contactor operation and relay functionality. Checked refrigerant line insulation for deterioration. Confirmed prope
Shaker Heights, OH 44120
Responded to no cooling complaint on 20+ year old air conditioning system. Upon arrival, inspected outdoor condensing unit which showed significant age and weathering with accumulated dirt and debris. Unit was positioned against building exterior in overgrown area with poor maintenance access. Evaluated indoor air handler equipment in basement mechanical room, noting aging coil assembly and refrigerant piping configuration. Due to system age exceeding expected service life and complete cooling failure, provided comprehensive estimate for full HVAC system replacement including new outdoor condensing unit and indoor air handler with associated refrigerant lines, electrical connections, and condensate drainage components.
Responded to no cooling complaint on 20+ year old air conditioning system. Upon arrival, inspected outdoor condensing unit which showed significant age and weathering with accumulated dirt and debris. Unit was positioned against building exterior in overgrown area with poor maintenance access. Evaluated indoor air handler equipment in basement mechanical room, noting aging coil assembly and refrigerant piping configuration. Due to system age exceeding expected service life and complete cooling failure, provided comprehensive estimate for full HVAC system replacement including new outdoor condensing unit and indoor air handler with associated refrigerant lines, electrical connections, and condensate drainage components.
VH S.
VH S. Checked in
Responded to no cooling complaint on 20+ year old air conditioning system. Upon arrival, inspected outdoor condensing unit which showed significant age and weathering with accumulated dirt and debris. Unit was positioned against building exterior in overgrown area with poor maintenance access. Evaluated indoor air handler equipment in basement mechanical room, noting aging coil assembly and refrigerant piping configuration. Due to system age exceeding expected service life and complete cooling failure, provided comprehensive estimate for full HVAC system replacement including new outdoor condensing unit and indoor air handler with associated refrigerant lines, electrical connections, and condensate drainage components.
Shaker Heights, OH 44122
Performed annual maintenance tune-up on one-year-old Bradford White tanked water heater including flush and fill procedure. Accommodated site conditions with drain located approximately 15 feet from unit. Inspected all connections, copper piping, expansion tank, pressure relief valve assembly, and water treatment components; verified proper operation of all systems and left unit in excellent working condition.
Performed annual maintenance tune-up on one-year-old Bradford White tanked water heater including flush and fill procedure. Accommodated site conditions with drain located approximately 15 feet from unit. Inspected all connections, copper piping, expansion tank, pressure relief valve assembly, and water treatment components; verified proper operation of all systems and left unit in excellent working condition.
Les B.
Les B. Checked in
Performed annual maintenance tune-up on one-year-old Bradford White tanked water heater including flush and fill procedure. Accommodated site conditions with drain located approximately 15 feet from unit. Inspected all connections, copper piping, expansion tank, pressure relief valve assembly, and water treatment components; verified proper operation of all systems and left unit in excellent working condition.
Shaker Heights, OH 44120
# HVAC Service Call - No Cooling Issue

Responded to service call for residential air conditioning system with outdoor unit running but no cold air delivery to interior spaces. Upon arrival, confirmed condenser unit fan motor operating normally with proper rotation observed at outdoor equipment location.

Performed comprehensive system diagnostics on Goodman model AUH1B060A9H31BA unit manufactured November 2016. Conducted visual inspection of outdoor condenser unit positioned on concrete pad against brick exterior wall. Verified electrical connections at wall-mounted disconnect panel and traced PVC conduit routing from electrical service to equipment. Examined indoor air handler specification label and recorded unit model and serial number for service documentation.

Diagnostic testing revealed system operational issues preventing proper cooling cycle. Checked refrigerant pressures, electrical voltages at unit terminals, and capacitor performance on both fan motor and compressor circui
# HVAC Service Call - No Cooling Issue

Responded to service call for residential air conditioning system with outdoor unit running but no cold air delivery to interior spaces. Upon arrival, confirmed condenser unit fan motor operating normally with proper rotation observed at outdoor equipment location.

Performed comprehensive system diagnostics on Goodman model AUH1B060A9H31BA unit manufactured November 2016. Conducted visual inspection of outdoor condenser unit positioned on concrete pad against brick exterior wall. Verified electrical connections at wall-mounted disconnect panel and traced PVC conduit routing from electrical service to equipment. Examined indoor air handler specification label and recorded unit model and serial number for service documentation.

Diagnostic testing revealed system operational issues preventing proper cooling cycle. Checked refrigerant pressures, electrical voltages at unit terminals, and capacitor performance on both fan motor and compressor circui
VH L.
VH L. Checked in
# HVAC Service Call - No Cooling Issue Responded to service call for residential air conditioning system with outdoor unit running but no cold air delivery to interior spaces. Upon arrival, confirmed condenser unit fan motor operating normally with proper rotation observed at outdoor equipment location. Performed comprehensive system diagnostics on Goodman model AUH1B060A9H31BA unit manufactured November 2016. Conducted visual inspection of outdoor condenser unit positioned on concrete pad against brick exterior wall. Verified electrical connections at wall-mounted disconnect panel and traced PVC conduit routing from electrical service to equipment. Examined indoor air handler specification label and recorded unit model and serial number for service documentation. Diagnostic testing revealed system operational issues preventing proper cooling cycle. Checked refrigerant pressures, electrical voltages at unit terminals, and capacitor performance on both fan motor and compressor circui
Shaker Heights, OH 44122
Completed replacement of steam radiator vents throughout the property. Removed old, corroded vents from multiple cast iron radiators and installed new brass air vents to ensure proper air release and efficient steam distribution. Work included accessing radiators in various rooms, removing accumulated debris from valve assemblies, and testing system operation upon completion. Customer also expressed interest in future installation of smart thermostat controls for the heating system.
Completed replacement of steam radiator vents throughout the property. Removed old, corroded vents from multiple cast iron radiators and installed new brass air vents to ensure proper air release and efficient steam distribution. Work included accessing radiators in various rooms, removing accumulated debris from valve assemblies, and testing system operation upon completion. Customer also expressed interest in future installation of smart thermostat controls for the heating system.
VH P.
VH P. Checked in
Completed replacement of steam radiator vents throughout the property. Removed old, corroded vents from multiple cast iron radiators and installed new brass air vents to ensure proper air release and efficient steam distribution. Work included accessing radiators in various rooms, removing accumulated debris from valve assemblies, and testing system operation upon completion. Customer also expressed interest in future installation of smart thermostat controls for the heating system.
Shaker Heights, OH 44122
Responded to service call for water heater flue pipe repair in century-old residential property. Upon inspection, identified deteriorated flue pipe connection at tanked water heater with compromised sealing around penetration point through masonry wall. Repaired flue pipe assembly to ensure proper venting of combustion gases and restored code-compliant connection between water heater exhaust and vertical vent stack. Verified secure mounting, proper draft operation, and eliminated potential carbon monoxide hazard. All work completed to current plumbing and safety standards.
Responded to service call for water heater flue pipe repair in century-old residential property. Upon inspection, identified deteriorated flue pipe connection at tanked water heater with compromised sealing around penetration point through masonry wall. Repaired flue pipe assembly to ensure proper venting of combustion gases and restored code-compliant connection between water heater exhaust and vertical vent stack. Verified secure mounting, proper draft operation, and eliminated potential carbon monoxide hazard. All work completed to current plumbing and safety standards.
Joseph M.
Joseph M. Checked in
Responded to service call for water heater flue pipe repair in century-old residential property. Upon inspection, identified deteriorated flue pipe connection at tanked water heater with compromised sealing around penetration point through masonry wall. Repaired flue pipe assembly to ensure proper venting of combustion gases and restored code-compliant connection between water heater exhaust and vertical vent stack. Verified secure mounting, proper draft operation, and eliminated potential carbon monoxide hazard. All work completed to current plumbing and safety standards.
Shaker Heights, OH 44122
Completed installation of customer-supplied American Standard toilet in small bathroom. Removed existing fixture and prepared floor flange connection. Installed new toilet, ensuring proper sealing at the base and secure mounting to floor. Verified proper operation of fill valve, flush mechanism, and drainage. No warranty provided on this installation as customer supplied the fixture.
Completed installation of customer-supplied American Standard toilet in small bathroom. Removed existing fixture and prepared floor flange connection. Installed new toilet, ensuring proper sealing at the base and secure mounting to floor. Verified proper operation of fill valve, flush mechanism, and drainage. No warranty provided on this installation as customer supplied the fixture.
Joseph M.
Joseph M. Checked in
Completed installation of customer-supplied American Standard toilet in small bathroom. Removed existing fixture and prepared floor flange connection. Installed new toilet, ensuring proper sealing at the base and secure mounting to floor. Verified proper operation of fill valve, flush mechanism, and drainage. No warranty provided on this installation as customer supplied the fixture.
Shaker Heights, OH 44122
Shaker Heights, OH - Completed comprehensive air conditioning tune-up and system performance evaluation. Utilized Fieldpiece SMAN refrigerant manifold with micron gauge to measure system pressures, temperatures, superheat, and subcooling values to verify proper refrigerant charge and overall system operation. All readings indicated the unit is functioning within normal parameters with no deficiencies identified.
VH-Samuel E.
VH-Samuel E. Checked in
Completed comprehensive air conditioning tune-up and system performance evaluation. Utilized Fieldpiece SMAN refrigerant manifold with micron gauge to measure system pressures, temperatures, superheat, and subcooling values to verify proper refrigerant charge and overall system operation. All readings indicated the unit is functioning within normal parameters with no deficiencies identified.
Shaker Heights, OH 44120
Responded to service call for routine maintenance on furnace and air conditioning system with reported water leak at furnace due to backup. Upon arrival, inspected 3-year-old gas furnace and found burner assembly operating with proper blue flame combustion. Examined blower motor, wiring connections, and lower compartment components for signs of water damage or obstruction. Investigated condensate drainage system to identify source of water backup causing leak. 

Proceeded to outdoor condensing unit to perform air conditioning system diagnostics. Utilized Testo 550 digital manifold gauge to measure refrigerant pressures and system temperatures. Recorded readings showing 48.2°F temperature with pressure measurements at 1028 and 2428 psi. Inspected condenser coils, which appeared clean and in good operational condition. Completed comprehensive system evaluation to ensure both heating and cooling systems were functioning properly and addressed water leak issue at furnace.
Responded to service call for routine maintenance on furnace and air conditioning system with reported water leak at furnace due to backup. Upon arrival, inspected 3-year-old gas furnace and found burner assembly operating with proper blue flame combustion. Examined blower motor, wiring connections, and lower compartment components for signs of water damage or obstruction. Investigated condensate drainage system to identify source of water backup causing leak. 

Proceeded to outdoor condensing unit to perform air conditioning system diagnostics. Utilized Testo 550 digital manifold gauge to measure refrigerant pressures and system temperatures. Recorded readings showing 48.2°F temperature with pressure measurements at 1028 and 2428 psi. Inspected condenser coils, which appeared clean and in good operational condition. Completed comprehensive system evaluation to ensure both heating and cooling systems were functioning properly and addressed water leak issue at furnace.
VH P.
VH P. Checked in
Responded to service call for routine maintenance on furnace and air conditioning system with reported water leak at furnace due to backup. Upon arrival, inspected 3-year-old gas furnace and found burner assembly operating with proper blue flame combustion. Examined blower motor, wiring connections, and lower compartment components for signs of water damage or obstruction. Investigated condensate drainage system to identify source of water backup causing leak. Proceeded to outdoor condensing unit to perform air conditioning system diagnostics. Utilized Testo 550 digital manifold gauge to measure refrigerant pressures and system temperatures. Recorded readings showing 48.2°F temperature with pressure measurements at 1028 and 2428 psi. Inspected condenser coils, which appeared clean and in good operational condition. Completed comprehensive system evaluation to ensure both heating and cooling systems were functioning properly and addressed water leak issue at furnace.
Shaker Heights, OH 44122
Completed full installation of dual-zone air conditioning system at residential property. Removed existing equipment and installed two complete AC systems in attic space, including outdoor condensing units, indoor air handlers, safety drain pans with wet switches, and programmable thermostats.

Positioned both outdoor condensers on level gravel pad adjacent to exterior stone wall, ensuring proper clearance for airflow and future maintenance access. Mounted units on vibration-dampening pads and completed all refrigerant line connections and electrical hookups per manufacturer specifications. Verified adequate spacing between units for optimal performance.

In attic, installed two air handler units on secondary drain pans with integrated wet switch float sensors to prevent water damage from potential condensate overflow. Configured PVC condensate drainage lines with proper pitch and secured all connections. Connected supply and return ductwork using insulated flexible ducting, ensuring p
Completed full installation of dual-zone air conditioning system at residential property. Removed existing equipment and installed two complete AC systems in attic space, including outdoor condensing units, indoor air handlers, safety drain pans with wet switches, and programmable thermostats.

Positioned both outdoor condensers on level gravel pad adjacent to exterior stone wall, ensuring proper clearance for airflow and future maintenance access. Mounted units on vibration-dampening pads and completed all refrigerant line connections and electrical hookups per manufacturer specifications. Verified adequate spacing between units for optimal performance.

In attic, installed two air handler units on secondary drain pans with integrated wet switch float sensors to prevent water damage from potential condensate overflow. Configured PVC condensate drainage lines with proper pitch and secured all connections. Connected supply and return ductwork using insulated flexible ducting, ensuring p
VH A.
VH A. Checked in
Completed full installation of dual-zone air conditioning system at residential property. Removed existing equipment and installed two complete AC systems in attic space, including outdoor condensing units, indoor air handlers, safety drain pans with wet switches, and programmable thermostats. Positioned both outdoor condensers on level gravel pad adjacent to exterior stone wall, ensuring proper clearance for airflow and future maintenance access. Mounted units on vibration-dampening pads and completed all refrigerant line connections and electrical hookups per manufacturer specifications. Verified adequate spacing between units for optimal performance. In attic, installed two air handler units on secondary drain pans with integrated wet switch float sensors to prevent water damage from potential condensate overflow. Configured PVC condensate drainage lines with proper pitch and secured all connections. Connected supply and return ductwork using insulated flexible ducting, ensuring p
Shaker Heights, OH 44120
# HVAC Complete System Installation

Successfully completed a full HVAC system installation in a residential basement mechanical room. Installed a new Bryant furnace as the primary heating unit, complete with all necessary ductwork connections including white rectangular supply ducts and black flexible ductwork. Integrated copper refrigerant lines and white PVC condensate drainage piping to ensure proper system operation and code compliance.

The installation included proper placement and mounting of the furnace unit on the concrete basement floor, with all required electrical connections, gas line hookups, and ventilation components. Connected the system to existing ductwork infrastructure at the ceiling level, ensuring proper airflow distribution throughout the residence. Installed filtration components and verified all access panels were properly secured with appropriate warning labels visible for future service needs.

All equipment was tested for proper operation, including verifi
# HVAC Complete System Installation

Successfully completed a full HVAC system installation in a residential basement mechanical room. Installed a new Bryant furnace as the primary heating unit, complete with all necessary ductwork connections including white rectangular supply ducts and black flexible ductwork. Integrated copper refrigerant lines and white PVC condensate drainage piping to ensure proper system operation and code compliance.

The installation included proper placement and mounting of the furnace unit on the concrete basement floor, with all required electrical connections, gas line hookups, and ventilation components. Connected the system to existing ductwork infrastructure at the ceiling level, ensuring proper airflow distribution throughout the residence. Installed filtration components and verified all access panels were properly secured with appropriate warning labels visible for future service needs.

All equipment was tested for proper operation, including verifi
VH J.
VH J. Checked in
# HVAC Complete System Installation Successfully completed a full HVAC system installation in a residential basement mechanical room. Installed a new Bryant furnace as the primary heating unit, complete with all necessary ductwork connections including white rectangular supply ducts and black flexible ductwork. Integrated copper refrigerant lines and white PVC condensate drainage piping to ensure proper system operation and code compliance. The installation included proper placement and mounting of the furnace unit on the concrete basement floor, with all required electrical connections, gas line hookups, and ventilation components. Connected the system to existing ductwork infrastructure at the ceiling level, ensuring proper airflow distribution throughout the residence. Installed filtration components and verified all access panels were properly secured with appropriate warning labels visible for future service needs. All equipment was tested for proper operation, including verifi
Shaker Heights, OH 44122
Shaker Heights, OH - Completed comprehensive pre-season air conditioning tune-up on a 10-year-old cooling system. Performed standard maintenance protocol including inspection of all major components, coil cleaning, refrigerant level verification, electrical connection testing, and filter replacement. System was brought online successfully with all parameters operating within normal specifications and ready for the cooling season.
VH-Samuel E.
VH-Samuel E. Checked in
Completed comprehensive pre-season air conditioning tune-up on a 10-year-old cooling system. Performed standard maintenance protocol including inspection of all major components, coil cleaning, refrigerant level verification, electrical connection testing, and filter replacement. System was brought online successfully with all parameters operating within normal specifications and ready for the cooling season.
Shaker Heights, OH 44120
Shaker Heights, OH - Responded to no heat call and diagnosed faulty control board on outdoor unit. Replaced defective board under warranty, restored heating operation, and verified system functionality. Performed air conditioning maintenance service including system inspection and testing with diagnostic gauges to ensure proper refrigerant levels and overall system performance.
VH-Samuel E.
VH-Samuel E. Checked in
Responded to no heat call and diagnosed faulty control board on outdoor unit. Replaced defective board under warranty, restored heating operation, and verified system functionality. Performed air conditioning maintenance service including system inspection and testing with diagnostic gauges to ensure proper refrigerant levels and overall system performance.
Shaker Heights, OH 44120

What To Expect

Discover the Verne & Ellsworth Hann Difference

Fully Licensed & Insured

Our licensed and insured experts have the knowledge and training to deliver the highest quality services every time.

5 Generations of Hann Family Experience

No other family has such a rich history in the heating, cooling, and plumbing needs of Northeast Ohio homeowners.

Financing Available

We offer various financing options to customers, so our HVAC and plumbing services are always accessible.

Highest Quality Services at an Honest Price

We provide unmatched repair, replacement, and maintenance with only the highest quality parts and equipment.

Commitment to Integrity & Professionalism

The Verne & Ellsworth Hann team is dedicated to ensuring honest and expert service every time.

Leader in Residential Heating & Cooling Since 1952

We have served the Cleveland area since 1952 and understand the community's HVAC and plumbing needs.

Fully Licensed & Insured

Our licensed and insured experts have the knowledge and training to deliver the highest quality services every time.

5 Generations of Hann Family Experience

No other family has such a rich history in the heating, cooling, and plumbing needs of Northeast Ohio homeowners.

Financing Available

We offer various financing options to customers, so our HVAC and plumbing services are always accessible.

Highest Quality Services at an Honest Price

We provide unmatched repair, replacement, and maintenance with only the highest quality parts and equipment.

Commitment to Integrity & Professionalism

The Verne & Ellsworth Hann team is dedicated to ensuring honest and expert service every time.

Leader in Residential Heating & Cooling Since 1952

We have served the Cleveland area since 1952 and understand the community's HVAC and plumbing needs.

Review Image
Our Reviews

See What Your Neighbors Are Saying

Verne & Ellsworth Hann, Inc installed a new boiler in our 100 year old home with expertise and craftsmanship. From the quote to the final instructions our experience was excellent! We highly recommend them! BILL R, MATT, KEITH, ADAM and GRAHAM were knowledgable, professional, friendly, punctual…

Laurie L.

Laurie L.

Hann installed central air in our nearly 100-year old home and did such a good job. They were communicative, prompt, and professional... and worked very hard to get the job done when they said it would be done. Would recommend them without hesitation.

Margaret F.

Margaret F.

We replaced our furnace/AC, updated our thermostat and replaced our water heater. It was an overall fantastic experience with Barry and Jayson; they showed up exactly when they said they would, worked steadily through both days, made sure we knew where they were on the installation…

Sarah H.

Sarah H.

We had them replace our old AC unit. They had the best price and were very professional in all aspects, from sales thru installation and payment. The installers were right on time and checked with me before doing anything that would result in a change from…

John R.

John R.

Really got us out of a bind. Completely replaced all of the plumbing - supply, drains, and waste - in one of our bathrooms. The shower had been leaking and was unusable, the pipes were 100 years old and half rotten. They were done in just…

Rob R.

Rob R.