Verne & Ellsworth Hann is renowned for outstanding HVAC and plumbing services! Being in business since 1907 makes us one of the oldest family-run companies in Cleveland Heights, OH. We offer the finest heating, air conditioning, plumbing, and boiler services to residents of Cleveland Heights.
To schedule top HVAC and plumbing services in Cleveland Heights, OH, call Verne & Ellsworth Hann at (216) 932-9755!

Dependable Heating & Cooling Services
Verne & Ellsworth Hann’s exceptional technicians can install, replace, repair, and maintain your heating or cooling system in Cleveland Heights, OH. You get consistently prompt, respectful service, no matter what type of issue you have.
We offer services for:
- Ductless mini-splits: This cost-effective, energy-efficient method of heating and cooling can be set for specific areas of your home, called zones, instead of having your whole house at one temperature.Â
- Heat pumps: A heat pump heats and cools your home. It’s environmentally safe, inconspicuous, and saves money. Our technicians and technology keep your heat pump working.
- Furnaces: Verne & Ellsworth Hann keeps your home warm in Cleveland Heights, OH! Our installation, repair, and maintenance services ensure your gas or electric furnace runs throughout the coldest Ohio winters.
- Boilers: We are the boiler specialists you want when your boiler requires installation, repair, or replacement. When you experience thermostat issues, system leaks, or lack of heat, turn to Verne & Ellsworth Hann!
- Packaged units: These combine heating and cooling components into a single, convenient unit, conserving space. If your packaged unit in Cleveland Heights, OH, needs to be installed, replaced, repaired, or maintained, Verne & Ellsworth Hann will do it!
Air Quality & Ductwork Services in Cleveland Heights
Excellent indoor air quality helps maintain good health. Verne & Ellsworth Hann’s indoor air quality solutions feature up-to-date technology so the air in your Cleveland Heights, OH, home is as pure as possible.
We handle installation, replacement, repair, and maintenance for:
- Air scrubbers: An air scrubber eliminates dust, pollutants, odors, and other unwanted particles from the air. It can be connected to your ductwork.
- Air purifiers: We provide state-of-the-art technology, like using UV light, to keep your air free of odors, particulates, germs, and mold.
- Whole-house humidifiers: Arid air causes issues with your eyes, mouth, nose, and lips. A whole-house humidifier maintains an ideal comfort level all the time.
Let Verne & Ellsworth Hann improve the indoor air quality of your Northeast Ohio home. Contact our team at (216) 932-9755!
Exceptional Plumbing Services
Since 1952, Verne & Ellsworth Hann has provided first-class plumbing services in Cleveland Heights, OH, addressing:
- Water heaters: We install, replace, and repair tankless, gas, and electric water heaters.
- Water lines: When there are soggy areas in your yard or your tap water is discolored, call us for water line installation, replacement, or repair!
- Gas lines: Problems with your gas line are dangerous. Exit your home immediately, contact your utility company, and let us pinpoint the issue and restore your peace of mind.
- Bathroom & kitchen plumbing: Don’t put up with a broken faucet, malfunctioning garbage disposal, or overflowing toilet! We’ll find the problem fast and correct it.
Verne & Ellsworth Hann is your source for outstanding plumbing services in Cleveland Heights, OH! Call (216) 932-9755 to schedule services today!
Choose Verne & Ellsworth Hann in Cleveland Heights, OH
You can trust Verne & Ellsworth Hann as your HVAC and plumbing partner in Northeast Ohio, including Cleveland Heights. We believe in professionalism, integrity, and transparency. Our licensed and insured techs uphold those standards and are happy to serve you!
We earned the Angi Super Service Award and Best of the Heights Award because of our knowledge, responsiveness, and dedication to satisfying each customer.
Call Verne & Ellsworth Hann at (216) 932-9755 to schedule HVAC or plumbing services in Cleveland Heights, OH, today!
Recent Jobs and Reviews in Cleveland Heights, OH
Job Locations and Reviews
Completed comprehensive air conditioning tune-up maintenance service with no reported issues at time of arrival. Performed system diagnostics including temperature differential measurements across the evaporator coil, recording supply air temperature of 63.6°F. Inspected indoor air handler unit, ductwork connections, and insulation integrity to ensure proper system operation and energy efficiency for the cooling season.
Completed annual air conditioning maintenance on a 23-year-old cooling system. Performed comprehensive inspection of the Trane furnace and associated HVAC components, including visual examination of internal wiring, electrical connections, and mechanical components with lower access panel removed for thorough access. Verified proper operation of humidifier/air handler unit and associated control systems. Inspected ductwork installation including black flexible insulated ducts and support systems throughout the mechanical space. Checked PVC condensate drainage system for proper flow and configuration, ensuring all connections and routing were secure and functional. Tested system electrical components using multimeter to verify proper voltage and amperage readings. Confirmed all equipment operating within manufacturer specifications for the cooling season.
Responded to AC unit repair call and performed diagnostic evaluation of residential air conditioning system. Connected Testo 550 digital manifold gauge to outdoor condenser unit and measured refrigerant pressures and temperatures for R410A system. Recorded suction pressure of 20.19 psi with corresponding temperature of 35°F, and discharge pressure of 68.5 psi with temperature of 48°F. Inspected indoor furnace and air handler components in basement, verifying proper ductwork connections and system configuration. Documented system conditions with diagnostic photos for service records. Unit operational following assessment.
Conducted comprehensive assessment of existing furnace system located in unfinished basement area for replacement estimate. Documented current HVAC unit configuration, including vertical furnace installation with multiple branch ductwork connections and return air grille. Evaluated existing ductwork infrastructure, noted exposed metallic distribution system extending across ceiling joists, and assessed flexible duct connections to primary unit. Photographed furnace cabinet with access panel open to document internal burner assembly and control components for replacement specifications. Property was unoccupied at time of inspection, accessed via lockbox per arrangement.
# HVAC Service Report
Performed annual air conditioning maintenance on an 18-year-old system. Conducted comprehensive diagnostics using digital manifold gauges to measure refrigerant pressures and temperatures, confirming R-22 refrigerant levels and system performance. All testing indicated the unit is operating within acceptable parameters for its age, and no immediate repairs were required at this time.
Completed annual cooling system maintenance on a 7-year-old residential air conditioning system. Performed comprehensive tune-up including inspection of outdoor condenser unit and indoor furnace/air handler, cleared vegetation growth from condenser louvers to restore proper airflow, verified all electrical connections, tested system operation, and confirmed equipment is functioning within normal parameters for the cooling season.
Completed full air conditioning system installation in residential property. Installed new outdoor condensing unit on concrete pad with new electrical disconnect box. Ran new copper refrigerant line set from outdoor unit to indoor air handler, properly insulated and secured. Mounted new Ecobee smart thermostat with remote sensor for zone temperature monitoring and programmed system settings. Installed condensate pump with PVC drainage piping to handle air handler condensate removal. Made all electrical connections, evacuated and charged refrigerant system to manufacturer specifications, and verified proper system operation including airflow, temperature differential, and thermostat communication.
Responded to emergency call for gas leak detected by gas company near recently installed Bradford White water heater. Upon arrival, gas supply was already shut off for safety. Conducted thorough pressure test on all gas lines and connections associated with the water heater installation. Inspected copper piping, brass fittings, and compression connections at top of unit for leaks using soap bubble solution and pressure testing equipment. Verified all connections at the gas control valve and burner assembly. Identified and repaired faulty connection point causing gas leak. Re-tested entire system to confirm leak was eliminated and all connections achieved proper seal. Restored gas supply and verified water heater ignition and proper operation. System tested and confirmed safe for continued use.
Completed comprehensive cooling maintenance on two air conditioning systems per annual Home Plan agreement. Performed full system inspections including blower assembly evaluation, airflow verification, and refrigerant pressure/temperature analysis using digital manifold gauges. Both units operating within manufacturer specifications with proper superheat and subcooling values confirmed.
Completed routine maintenance and tune-up on dual-system HVAC installation consisting of basement furnace and attic furnace unit. Performed comprehensive inspection of both four-year-old furnace systems including burner assembly, heat exchanger, gas connections, electrical components, and venting. Verified proper operation of blower motors, checked air filters, tested safety controls, and confirmed all mechanical and plumbing connections were secure with no leaks detected. Both systems operating within manufacturer specifications with no issues found.
Responded to emergency service call for A/C unit in finished attic space leaking water through ceiling, causing significant structural damage and partial ceiling collapse. Upon inspection, located Carrier HVAC system in attic crawl space and assessed condensate drainage system for blockages or failures. Documented extensive ceiling damage in living area below unit, including compromised decorative plaster and exposed backing material, and photographed equipment installation including furnace unit, ductwork, PVC condensate piping, and condensate pump to identify source of water intrusion.
Performed comprehensive summer tune-up on residential air conditioning system with no reported issues. Connected digital manifold gauges to measure refrigerant pressures and temperatures, verified proper system operation and airflow across condenser coil. All readings within manufacturer specifications, unit operating normally upon completion of preventive maintenance inspection.
Responded to service call for toilet evaluation and replacement quote. Upon arrival, assessed existing standard two-piece white porcelain toilet with raised seat and lid. Customer requested replacement with comfort-height (ADA-compliant) toilet featuring high-flush performance capability. Inspected current installation including water supply line, shut-off valve, floor flange connection, and mounting configuration against subway-tiled wall. Documented existing floor tile pattern and spatial constraints for replacement unit specifications. Photographed current fixture and surrounding area to provide accurate measurements and installation requirements for quote preparation. Provided customer with recommendations for comfort-height toilet models with enhanced flushing systems suitable for their needs.
Performed comprehensive tune-up on 20-year-old Lennox air conditioning system. Conducted complete system diagnostics using manifold gauges to verify refrigerant pressures and temperatures across both the outdoor condensing unit and indoor air handler. All readings were within manufacturer specifications, confirming proper system operation and refrigerant charge. Inspected electrical components, cleaned condenser coils, and verified proper airflow throughout the system. Unit operating efficiently with no deficiencies noted.
Conducted on-site HVAC system evaluation for equipment replacement estimate in residential basement mechanical room. Assessed existing Carrier furnace installation, electrical panel capacity, ductwork configuration, and PVC venting system to determine replacement specifications and installation requirements.
Arrived on-site to assess existing HVAC system for replacement estimate. Evaluated outdoor air conditioning unit positioned against brick wall, noting vegetation overgrowth around condenser requiring clearance for proper airflow and serviceability. Inspected indoor furnace installation in basement, including ductwork, plenum connections, and associated piping. Documented equipment conditions and took photographs of both outdoor and indoor units to support replacement proposal.
Completed scheduled preventive maintenance on two 5-year-old air conditioning systems. Performed comprehensive system diagnostics using refrigerant manifold and micron gauge to verify proper refrigerant pressures, temperatures, and system performance on both units. All equipment inspected, tested, and confirmed to be operating within manufacturer specifications.
Responded to service call for newly installed A/C system running continuously and struggling to maintain setpoint temperature. Connected manifold gauges to evaluate system performance and recorded operating pressures and temperatures. Low side pressure measured 93 psig with 22.8°F saturation temperature, high side pressure measured 251 psig with 108.6°F discharge temperature. System showed 9.9°F subcooling and 8.75°F superheat, indicating refrigerant charge and metering device were operating within acceptable parameters for current ambient conditions.
Performed diagnostic evaluation on second floor air handler system experiencing inadequate cooling. After thorough assessment of the second floor layout and existing HVAC configuration, determined the current system capacity is undersized for the cooling load requirements of the space. Documented existing Concord outdoor condensing unit and electrical panel configuration for replacement estimate preparation.
Responded to no cooling call on 6-year-old Allied Air Enterprises AC system (Model 4SCU13LE136P). Upon arrival, confirmed unit was running but no airflow at interior vents affecting entire home. Performed diagnostic testing using refrigerant manifold and micron gauge, measuring system pressures at 112.3 psig low side and 276.6 psig high side with corresponding temperatures. Identified and resolved airflow issue, restoring proper cooling operation to all zones.