Verne & Ellsworth Hann is renowned for outstanding HVAC and plumbing services! Being in business since 1907 makes us one of the oldest family-run companies in Cleveland Heights, OH. We offer the finest heating, air conditioning, plumbing, and boiler services to residents of Cleveland Heights.
To schedule top HVAC and plumbing services in Cleveland Heights, OH, call Verne & Ellsworth Hann at (216) 932-9755!

Dependable Heating & Cooling Services
Verne & Ellsworth Hann’s exceptional technicians can install, replace, repair, and maintain your heating or cooling system in Cleveland Heights, OH. You get consistently prompt, respectful service, no matter what type of issue you have.
We offer services for:
- Ductless mini-splits: This cost-effective, energy-efficient method of heating and cooling can be set for specific areas of your home, called zones, instead of having your whole house at one temperature.Â
- Heat pumps: A heat pump heats and cools your home. It’s environmentally safe, inconspicuous, and saves money. Our technicians and technology keep your heat pump working.
- Furnaces: Verne & Ellsworth Hann keeps your home warm in Cleveland Heights, OH! Our installation, repair, and maintenance services ensure your gas or electric furnace runs throughout the coldest Ohio winters.
- Boilers: We are the boiler specialists you want when your boiler requires installation, repair, or replacement. When you experience thermostat issues, system leaks, or lack of heat, turn to Verne & Ellsworth Hann!
- Packaged units: These combine heating and cooling components into a single, convenient unit, conserving space. If your packaged unit in Cleveland Heights, OH, needs to be installed, replaced, repaired, or maintained, Verne & Ellsworth Hann will do it!
Air Quality & Ductwork Services in Cleveland Heights
Excellent indoor air quality helps maintain good health. Verne & Ellsworth Hann’s indoor air quality solutions feature up-to-date technology so the air in your Cleveland Heights, OH, home is as pure as possible.
We handle installation, replacement, repair, and maintenance for:
- Air scrubbers: An air scrubber eliminates dust, pollutants, odors, and other unwanted particles from the air. It can be connected to your ductwork.
- Air purifiers: We provide state-of-the-art technology, like using UV light, to keep your air free of odors, particulates, germs, and mold.
- Whole-house humidifiers: Arid air causes issues with your eyes, mouth, nose, and lips. A whole-house humidifier maintains an ideal comfort level all the time.
Let Verne & Ellsworth Hann improve the indoor air quality of your Northeast Ohio home. Contact our team at (216) 932-9755!
Exceptional Plumbing Services
Since 1952, Verne & Ellsworth Hann has provided first-class plumbing services in Cleveland Heights, OH, addressing:
- Water heaters: We install, replace, and repair tankless, gas, and electric water heaters.
- Water lines: When there are soggy areas in your yard or your tap water is discolored, call us for water line installation, replacement, or repair!
- Gas lines: Problems with your gas line are dangerous. Exit your home immediately, contact your utility company, and let us pinpoint the issue and restore your peace of mind.
- Bathroom & kitchen plumbing: Don’t put up with a broken faucet, malfunctioning garbage disposal, or overflowing toilet! We’ll find the problem fast and correct it.
Verne & Ellsworth Hann is your source for outstanding plumbing services in Cleveland Heights, OH! Call (216) 932-9755 to schedule services today!
Choose Verne & Ellsworth Hann in Cleveland Heights, OH
You can trust Verne & Ellsworth Hann as your HVAC and plumbing partner in Northeast Ohio, including Cleveland Heights. We believe in professionalism, integrity, and transparency. Our licensed and insured techs uphold those standards and are happy to serve you!
We earned the Angi Super Service Award and Best of the Heights Award because of our knowledge, responsiveness, and dedication to satisfying each customer.
Call Verne & Ellsworth Hann at (216) 932-9755 to schedule HVAC or plumbing services in Cleveland Heights, OH, today!
Recent Jobs and Reviews in Cleveland Heights, OH
Job Locations and Reviews
Conducted comprehensive evaluation of existing HVAC system for complete furnace and air conditioning replacement estimate. Assessed current equipment configuration including furnace unit with diamond-pattern louvered access panel, existing ductwork system, and associated PVC condensate drainage lines. Documented mechanical room layout, equipment placement, and existing infrastructure including electrical connections, gas piping, and ventilation components to determine optimal replacement specifications and installation requirements.
Responded to service call for a five-year-old air conditioning system experiencing freeze-up conditions at the outdoor condenser unit. Performed initial assessment of the exterior condensing unit located at ground level with easy stairway access, noting frozen coil condition that required defrost time before completing full diagnostic evaluation. Scheduled follow-up appointment to return same day in the afternoon to complete comprehensive diagnostic testing once unit had adequate time to thaw and determine root cause of freeze-up issue, with possible air handler inspection needed in attic space.
Completed evaporator coil replacement under parts warranty in attic-mounted HVAC system. Removed failed evaporator coil and installed new unit, reconnected refrigerant lines, verified proper drainage through PVC condensate system, and tested system operation to ensure proper cooling performance. All components functioning within manufacturer specifications upon completion.
Completed installation of 2-ton multi-zone mini split system on residential property with turquoise-blue sided upper level. Installed three indoor air handling units: 9,000 BTU unit in bedroom, 9,000 BTU unit in kitchen, and 12,000 BTU console unit in living room. Mounted outdoor condensing unit (model 37MGHAQ24DA301) on exterior wall, verified proper electrical connections at 208/230V, 60Hz, 1Ph power supply, and completed refrigerant line sets between outdoor unit and all three zones. System utilizes A2L refrigerant classification per manufacturer specifications. Confirmed all safety labels and wiring diagrams are visible and legible on equipment. Tested system operation across all zones to ensure proper cooling function and airflow distribution.
Performed comprehensive air conditioning tune-up on 6-year-old Bryant condenser unit. Inspected all major components including compressor, condenser coil, fan motor assembly, and electrical connections; verified proper refrigerant levels and system operation. Unit tested and confirmed operating within manufacturer specifications with no issues found.
Completed full installation of Peerless Steam boiler model 63-04 in residential basement location, replacing existing heating system. Installation included mounting and connecting new boiler unit, installing automatic water feeder with backflow preventer for proper water supply protection, mounting new pressure control and low water cutoff safety devices, installing new sight glass for water level monitoring, and wiring new thermostat for system control. All steam piping connections were completed, system was pressure tested, and unit was fired and commissioned to verify proper operation of all safety controls and heating functionality.
Completed comprehensive cooling maintenance on a 2-year-old Trane system. Performed full AC tune-up including inspection of electrical connections, refrigerant pressures, and condenser unit operation. All components tested within manufacturer specifications and system operating efficiently.
Responded to service call for second-floor air handler experiencing intermittent operation with startup noise but no fan or cooling function. Upon inspection, accessed control panel and identified wiring and control board issues preventing proper system operation. Examined circuit boards, wire connections, and control components within the air handler compartment. Verified proper wire terminations at connection points and inspected condition of control boards and associated wiring harnesses. Documented internal panel configuration and component layout showing multiple wire connections, circuit boards, and control relays. System evaluated for electrical continuity and proper control voltage at connection terminals.
Installed new stop valve and supply line on existing copper piping in residential utility area. Installed 1-1/4" press ball valve with brass fittings to replace water feed serving humidifier and ice maker. Verified proper operation of all water supply connections upon completion.
Responded to no cooling complaint on residential air conditioning system over 10 years old. Upon arrival, found outdoor condenser unit operational but indoor evaporator coil frozen with active water leakage from condensate system. Inspected airflow pathways and refrigerant circuit, documented equipment condition and drainage configuration with overgrown vegetation around outdoor unit potentially restricting airflow. System exhibited symptoms consistent with reduced airflow or low refrigerant charge causing coil freeze-up and subsequent water discharge.
Completed preventive maintenance on three residential air conditioning units. Performed comprehensive inspection of outdoor condenser unit, verifying proper operation of compressor, condenser fan motor, and electrical connections. Inspected indoor air handler and furnace system, checked condensate drainage lines and humidifier operation. All units tested and confirmed operational. Customer renewed maintenance plan agreement with technician on-site.
Completed installation of add-on air conditioning system to existing Carrier furnace in basement utility area. Integrated new AC components with existing ductwork infrastructure, installed necessary refrigerant lines, condensate drainage, and electrical connections to provide cooling capability while maintaining existing heating system functionality.
Completed full installation of Unico high-velocity air conditioning system featuring 2-stage cooling capability. Installed new outdoor condenser unit on concrete pad with electrical disconnect box, new indoor evaporator coil module, and blower module in attic space with proper platform mounting. Ran refrigerant lines between outdoor and indoor units, installed new condensate drain pan with drainage piping, and wired new programmable thermostat for system control. Added 10 additional supply outlets with flexible ductwork throughout the residence to ensure proper airflow distribution and system performance. All equipment tested and verified operational with proper airflow, refrigerant charge, and temperature differential across the coil.
Completed comprehensive cooling maintenance on a 15-year-old residential air conditioning system. Performed standard tune-up procedures including inspection of outdoor condensing unit, verification of refrigerant line connections, evaluation of electrical components and conduit connections, and assessment of overall system operation. Unit was found to be functioning properly with all components operating within normal parameters at time of service.
Completed installation of Bryant split-system air conditioning system including outdoor condenser unit, attic-mounted air handler, and new ductwork throughout the home. The outdoor condenser was positioned on a pad against the brick exterior with proper clearances maintained, electrical disconnect box installed and labeled for both air handler and condenser circuits, and refrigerant lines run to the attic air handler. All new ductwork was installed in the attic space to provide cooling to the entire second floor, with additional supply runs extended to the first-floor living room and kitchen areas as space permitted. Electrical connections were completed with appropriate circuit protection, and the system was tested for proper operation upon completion.
Performed routine preventive maintenance tune-up on a Trane XR series air conditioning system (Model 4TTR3030H1000NA, manufactured May 2017). Conducted comprehensive inspection of the outdoor condensing unit, verified proper operation of all components, and confirmed system specifications matched nameplate data. No deficiencies were identified during the inspection, and the unit was found to be operating within normal parameters for an 8-9 year old system.
Completed preventive maintenance tune-up on two 4-year-old air conditioning systems. Performed comprehensive inspection of both units including condenser coil cleaning, blower wheel examination, and verification of all mechanical components. All systems operating within manufacturer specifications with no deficiencies noted.
Performed routine maintenance cooling system inspection on a 4-year-old air handler unit. Conducted comprehensive evaluation of indoor air handler components including blower assembly, evaporator coil, and ductwork condition. Inspected outdoor condensing unit mounted on rooftop platform, verifying proper operation of compressor, condenser fan motor, and refrigerant lines. Examined electrical connections at disconnect box and service panel, confirming secure wiring and proper voltage supply. Cleared accumulated debris from around condenser unit base and roof perimeter to ensure adequate airflow and prevent potential drainage issues. System operating within normal parameters with no immediate repairs required at time of service.
Performed annual maintenance on 15-year-old Bryant air conditioning system. Completed standard tune-up procedures including inspection of outdoor condensing unit, verification of refrigerant levels, cleaning of condenser coils, and evaluation of electrical connections and components. Unit operational at time of service completion.
Responded to service call for abnormal water consumption indicated by significant increase in monthly water bill. Performed diagnostic inspection of exterior plumbing system including main water line, irrigation connections, and pressure regulation components. Identified issue with exterior PVC piping assembly and associated valves mounted on building exterior. Inspected filter housing, pressure regulation system, and multiple connection points for signs of leakage or system malfunction that would account for excessive water usage.