Verne & Ellsworth Hann is renowned for outstanding HVAC and plumbing services! Being in business since 1907 makes us one of the oldest family-run companies in Cleveland Heights, OH. We offer the finest heating, air conditioning, plumbing, and boiler services to residents of Cleveland Heights.
To schedule top HVAC and plumbing services in Cleveland Heights, OH, call Verne & Ellsworth Hann at (440) 363-6815!

Dependable Heating & Cooling Services
Verne & Ellsworth Hann’s exceptional technicians can install, replace, repair, and maintain your heating or cooling system in Cleveland Heights, OH. You get consistently prompt, respectful service, no matter what type of issue you have.
We offer services for:
- Ductless mini-splits: This cost-effective, energy-efficient method of heating and cooling can be set for specific areas of your home, called zones, instead of having your whole house at one temperature.Â
- Heat pumps: A heat pump heats and cools your home. It’s environmentally safe, inconspicuous, and saves money. Our technicians and technology keep your heat pump working.
- Furnaces: Verne & Ellsworth Hann keeps your home warm in Cleveland Heights, OH! Our installation, repair, and maintenance services ensure your gas or electric furnace runs throughout the coldest Ohio winters.
- Boilers: We are the boiler specialists you want when your boiler requires installation, repair, or replacement. When you experience thermostat issues, system leaks, or lack of heat, turn to Verne & Ellsworth Hann!
- Packaged units: These combine heating and cooling components into a single, convenient unit, conserving space. If your packaged unit in Cleveland Heights, OH, needs to be installed, replaced, repaired, or maintained, Verne & Ellsworth Hann will do it!
Air Quality & Ductwork Services in Cleveland Heights
Excellent indoor air quality helps maintain good health. Verne & Ellsworth Hann’s indoor air quality solutions feature up-to-date technology so the air in your Cleveland Heights, OH, home is as pure as possible.
We handle installation, replacement, repair, and maintenance for:
- Air scrubbers: An air scrubber eliminates dust, pollutants, odors, and other unwanted particles from the air. It can be connected to your ductwork.
- Air purifiers: We provide state-of-the-art technology, like using UV light, to keep your air free of odors, particulates, germs, and mold.
- Whole-house humidifiers: Arid air causes issues with your eyes, mouth, nose, and lips. A whole-house humidifier maintains an ideal comfort level all the time.
Let Verne & Ellsworth Hann improve the indoor air quality of your Northeast Ohio home. Contact our team at (440) 363-6815!
Exceptional Plumbing Services
Since 1952, Verne & Ellsworth Hann has provided first-class plumbing services in Cleveland Heights, OH, addressing:
- Water heaters: We install, replace, and repair tankless, gas, and electric water heaters.
- Water lines: When there are soggy areas in your yard or your tap water is discolored, call us for water line installation, replacement, or repair!
- Gas lines: Problems with your gas line are dangerous. Exit your home immediately, contact your utility company, and let us pinpoint the issue and restore your peace of mind.
- Bathroom & kitchen plumbing: Don’t put up with a broken faucet, malfunctioning garbage disposal, or overflowing toilet! We’ll find the problem fast and correct it.
Verne & Ellsworth Hann is your source for outstanding plumbing services in Cleveland Heights, OH! Call (440) 363-6815 to schedule services today!
Choose Verne & Ellsworth Hann in Cleveland Heights, OH
You can trust Verne & Ellsworth Hann as your HVAC and plumbing partner in Northeast Ohio, including Cleveland Heights. We believe in professionalism, integrity, and transparency. Our licensed and insured techs uphold those standards and are happy to serve you!
We earned the Angi Super Service Award and Best of the Heights Award because of our knowledge, responsiveness, and dedication to satisfying each customer.
Call Verne & Ellsworth Hann at (440) 363-6815 to schedule HVAC or plumbing services in Cleveland Heights, OH, today!
Verne and Ellsworth Hann has completed 20 jobs in Cleveland Heights, OH in June 2026. The most recent job was on June 18, 2026. Verne and Ellsworth Hann has completed 1,426 jobs in Cleveland Heights, OH in the last 12 months.Recent Jobs and Reviews in Cleveland Heights, OH
Cleveland Heights, OH at a glance
Job Locations and Reviews
Performed comprehensive tune-up on 20-year-old Lennox air conditioning system. Conducted complete system diagnostics using manifold gauges to verify refrigerant pressures and temperatures across both the outdoor condensing unit and indoor air handler. All readings were within manufacturer specifications, confirming proper system operation and refrigerant charge. Inspected electrical components, cleaned condenser coils, and verified proper airflow throughout the system. Unit operating efficiently with no deficiencies noted.
Conducted on-site HVAC system evaluation for equipment replacement estimate in residential basement mechanical room. Assessed existing Carrier furnace installation, electrical panel capacity, ductwork configuration, and PVC venting system to determine replacement specifications and installation requirements.
Arrived on-site to assess existing HVAC system for replacement estimate. Evaluated outdoor air conditioning unit positioned against brick wall, noting vegetation overgrowth around condenser requiring clearance for proper airflow and serviceability. Inspected indoor furnace installation in basement, including ductwork, plenum connections, and associated piping. Documented equipment conditions and took photographs of both outdoor and indoor units to support replacement proposal.
Completed scheduled preventive maintenance on two 5-year-old air conditioning systems. Performed comprehensive system diagnostics using refrigerant manifold and micron gauge to verify proper refrigerant pressures, temperatures, and system performance on both units. All equipment inspected, tested, and confirmed to be operating within manufacturer specifications.
Responded to service call for newly installed A/C system running continuously and struggling to maintain setpoint temperature. Connected manifold gauges to evaluate system performance and recorded operating pressures and temperatures. Low side pressure measured 93 psig with 22.8°F saturation temperature, high side pressure measured 251 psig with 108.6°F discharge temperature. System showed 9.9°F subcooling and 8.75°F superheat, indicating refrigerant charge and metering device were operating within acceptable parameters for current ambient conditions.
Performed diagnostic evaluation on second floor air handler system experiencing inadequate cooling. After thorough assessment of the second floor layout and existing HVAC configuration, determined the current system capacity is undersized for the cooling load requirements of the space. Documented existing Concord outdoor condensing unit and electrical panel configuration for replacement estimate preparation.
Responded to no cooling call on 6-year-old Allied Air Enterprises AC system (Model 4SCU13LE136P). Upon arrival, confirmed unit was running but no airflow at interior vents affecting entire home. Performed diagnostic testing using refrigerant manifold and micron gauge, measuring system pressures at 112.3 psig low side and 276.6 psig high side with corresponding temperatures. Identified and resolved airflow issue, restoring proper cooling operation to all zones.
Completed seasonal cooling maintenance and tune-up on residential air conditioning system. Performed comprehensive inspection of outdoor condensing unit, checked refrigerant levels, cleaned condenser coils, verified electrical connections, and tested system operation to ensure optimal performance for the cooling season.
Responded to return service call for mini split system experiencing water leakage despite previous condensate drain clearing. Upon arrival, inspected attic-mounted unit and drainage system. Re-cleared condensate drain line using compressed air and flushed with cleaning vinegar to prevent future clogs and ensure proper drainage operation.
Performed comprehensive AC tune-up on outdoor condenser unit located in below-grade window well area. Completed full system inspection including electrical connections, refrigerant levels, condenser coil cleaning, and operational testing. Unit operating within normal parameters with no issues identified; all components functioning properly at time of service.
Replaced defective thermal expansion valve (TXV) on HVAC system. System was evacuated, TXV was removed and new valve installed, then system was recharged and leak tested. Vacuum test confirmed proper system integrity at 3.2 microns before refrigerant recharge.
Completed routine maintenance and tune-up on 6-year-old air conditioning system. Performed comprehensive system checkup including temperature differential readings, which measured at 45.59°F and 45.69°F, indicating proper cooling performance. Replaced air filters as scheduled, inspected all components, and verified system operation with no issues found.
Replaced wye strainer on copper water supply line in ceiling space. Removed existing strainer assembly and installed new unit with proper brass fittings and compression connections to restore proper filtration and flow to the plumbing system.
Performed initial maintenance visit on 21-year-old 8-ton air conditioning unit. Confirmed system operational status during first service call, documented equipment condition with photos showing outdoor condensing unit properly positioned on concrete pad with adequate clearance and vegetation management.
Responded to service call for Bryant CVPVA3017XMCEAAA central air conditioning unit experiencing recurring freeze-up issues despite previous inspection and regular maintenance. Performed comprehensive diagnostic evaluation of the R-410A system, including inspection of refrigerant charge levels, airflow measurements, TXV metering device operation, and evaporator coil condition to identify root cause of repeated freezing events occurring under normal operating conditions.
Completed annual air conditioning tune-up on 12-year-old residential cooling system. Performed comprehensive maintenance including inspection of condensing unit, verification of electrical connections and wiring, testing of fan motor operation, and evaluation of overall system performance. Unit found to be operating within normal parameters with no issues identified or repairs required.
Completed revised estimate for whole-home mini split system installation consisting of three indoor head units and one outdoor compressor. Assessed custom placement locations for indoor units as specified by homeowner, with particular attention to exterior aesthetics and visual impact. Documented existing conditions including bedroom with window AC unit and kitchen area to determine optimal head unit positioning that accommodates ongoing bathroom remodeling project while maintaining system efficiency and meeting homeowner's specific placement requirements.
Responded to service call for tankless water heater displaying error code in century-old residential property. Upon arrival, performed diagnostic assessment of unit previously installed by our company. Inspected digital control panel, verified error code, and examined all copper pipe connections and shut-off valves for proper operation. Cleared debris from water inlet strainer which had accumulated sediment and organic material causing flow restriction and triggering fault condition. Tested all plumbing connections, confirmed proper gas supply and venting, and verified Energy Star certified unit returned to normal operating parameters. Reset system, monitored through complete heating cycle, and ensured hot water delivery restored to all fixtures. Unit now functioning properly with no error codes displayed.
Removed toilet and chipped away concrete around flange to access subfloor structure. Installed support boards beneath flange and additional blocking to reinforce bottom side of drain elbow. Reinstalled toilet with new wax ring, secured mounting bolts, and applied silicone bead around base. Performed leak test and operational check, verified no rocking or movement of fixture.
Completed comprehensive HVAC estimate for dual system replacement including attic-mounted air handler and basement furnace unit. Assessment included evaluation for concrete equipment pad installation and security cage requirements to protect exterior condensing units from potential damage or theft.