When it comes to dependable HVAC and plumbing solutions in University Heights, OH, Verne & Ellsworth Hann is the name you can trust. With over a century of experience and five generations of local expertise, we’re proud to serve Northeast Ohio with professional HVAC and plumbing services. Our licensed and insured technicians deliver exceptional service to ensure your home stays comfortable and safe year-round.
If you need expert HVAC or plumbing services, look no further than Verne & Ellsworth. Contact us today to schedule your appointment.

Exceptional Heating Repair & Replacement Services
As temperatures drop in University Heights, ensuring your heating is reliable is important. At Verne & Ellsworth Hann, we specialize in heating repair, installation, replacement, and maintenance services for all major heating systems.
Gas & Electric Furnaces
Gas and electric furnaces are among the most common heating systems. Our technicians are equipped to handle any furnace issue, whether you need a quick repair or a complete system replacement. We also recommend routine maintenance to ensure optimal performance and energy efficiency.
Boilers
Boilers are great for providing consistent, efficient heat. As Northeast Ohio’s boiler experts, we offer comprehensive boiler services, including installation, repair, and maintenance. Whether you need a new energy-efficient boiler or a repair for an existing unit, we’ve got you covered.
Heat Pumps
Heat pumps offer an energy-efficient solution for heating and cooling. Our team provides expert installation, repair, and maintenance services to ensure proper heat pump operation.
Radiators
Whether you have a cast-iron, steel, or copper radiator in your University Heights home, the Verne & Ellsworth Hann team can assist with its repair, replacement, or maintenance.
Dependable Cooling & AC Services
Stay cool and comfortable during Ohio’s summer months with our reliable cooling services. Verne & Ellsworth Hann delivers top-notch installation, repair, and maintenance for all types of air conditioning systems.
Ductless Mini-Splits
Ductless mini-split systems provide flexible and efficient cooling solutions for any space. Whether you’re adding cooling to a specific room or need an entirely new system, we offer expert installation and maintenance to keep your mini-split running smoothly.
High-Velocity ACs
High-velocity AC systems are perfect for homes with limited space for traditional ductwork. Our skilled technicians specialize in installing and servicing these systems, ensuring you enjoy consistent cooling without compromising your home’s design.
Air Quality & Ductwork Services in University Heights
Breathe easier with our comprehensive air quality and ductwork solutions. Verne & Ellsworth Hann can help improve your home’s indoor air environment through our innovative services and products.
- Air scrubbers and cleaners:Â Advanced air scrubbers and cleaners eliminate harmful particles and allergens. Our solutions ensure cleaner, healthier air for you and your family.
- Carbon monoxide detection: We install and maintain carbon monoxide detectors to protect your home and loved ones from this silent threat.
- Whole-house humidifiers and dehumidifiers: Our whole-house humidifiers and dehumidifiers help maintain the perfect humidity level year-round. These systems prevent dry air in winter and excess moisture in summer, keeping your home comfortable.
Trusted Plumbing & Drain Services
Verne & Ellsworth Hann offers a full suite of plumbing and drain services to meet the needs of University Heights homeowners. From water heaters to drain cleaning, our team delivers expert solutions with outstanding customer care. Our services include:
- Water heaters: Whether you need a repair, replacement, or upgrade to a tankless system, our water heater services ensure consistent hot water for your home.
- Water lines: If you need repairs on your water lines, we’re the ones to call.
- Gas lines: We provide reliable installation and repair services for gas lines.
- Drain snaking: Our drain snaking services effectively remove blockages to restore your plumbing system.
Schedule in University Heights With Verne & Ellsworth Hann Today
When you choose Verne & Ellsworth Hann, you partner with a company that values integrity, expertise, and customer satisfaction. As a locally operated business founded in 1907, we bring unmatched experience to every job.
Don’t wait to schedule services – contact Verne & Ellsworth Hann today.
Recent Jobs and Reviews in University Heights, OH
Job Locations and Reviews
Completed routine maintenance on a 5-year-old air conditioning system. Inspected and photographed blower wheel assembly, confirming proper blade alignment and cleanliness of centrifugal fan components. All system components operating within normal parameters with no deficiencies noted.
Performed comprehensive cooling system maintenance and diagnostics on air conditioning unit. Utilized digital manifold gauges to measure system pressures and temperatures, recording readings of 256 psig high-side and 225.0 psig low-side pressure, with superheat and subcooling values within acceptable parameters. System operating efficiently with no refrigerant leaks detected and all components functioning properly.
Responded to concern of possible carbon monoxide leak from furnace exhaust vent following recent gas main replacement on 12-year-old unit that had not been serviced in four years. Performed comprehensive safety inspection of furnace system, including visual examination of heat exchanger for cracks or deterioration, combustion analysis, and CO testing at vent termination point. Heat exchanger showed normal condensation patterns with no visible breaches or structural damage. All safety checks confirmed proper combustion and venting with no detectable carbon monoxide present at exhaust or in living space.
Conducted site assessment for dryer vent installation through existing glass block window in utility area. Evaluated structural conditions including deteriorated wooden window frame and exposed ceiling joists with existing electrical wiring running through cavity. Documented current conditions and photographed installation location to determine appropriate venting solution and materials needed for future dryer exhaust system installation.
Conducted on-site assessment for HVAC system replacement. Documented existing Goodman ASXE16030TF4 air handler unit specifications, including electrical ratings of 208-230V and relevant model information for replacement planning. Evaluated current basement installation configuration, including existing ductwork connections, supply plenums, and insulated refrigerant lines. Photographed equipment labels and mechanical room layout to provide comprehensive documentation for preparing replacement estimate and ensuring proper equipment sizing for the application.
Completed annual preventative maintenance on residential air conditioning system. Performed comprehensive system diagnostics using Fieldpiece SMAN refrigerant manifold and micron gauge to measure operating pressures and temperatures across all zones. Inspected outdoor condensing unit including condenser coils, which showed normal seasonal wear with minor discoloration on fins. Verified refrigerant charge levels and system performance parameters within manufacturer specifications. All components operating properly with no deficiencies noted at time of service.
Completed routine maintenance tune-up on three-year-old furnace and air conditioning system. Performed comprehensive inspection of both units, including cleaning of outdoor condenser coils which showed debris accumulation on protective grille, checked refrigerant levels, tested electrical connections, and verified proper airflow through ventilation components. Both systems operating within normal parameters with no issues identified.
Conducted comprehensive assessment of existing York furnace and air conditioning system for equipment replacement estimate. Documented current HVAC installation including furnace unit, ductwork configuration, electrical components, and PVC venting system in basement utility area. Evaluated equipment condition, system layout, and spatial considerations to provide accurate replacement recommendations and specifications.
Conducted on-site evaluation for complete HVAC system replacement at residential property with 26-year-old existing equipment. Assessed current basement-mounted furnace installation with associated ductwork configuration and outdoor condensing unit positioned on concrete pad against exterior foundation. Documented existing system components, mechanical room layout, and outdoor unit placement for replacement specifications and equipment sizing recommendations.
Completed comprehensive AC tune-up on an 8-year-old Goodman air conditioning system. System was found to be functioning properly during maintenance inspection. Customer enrolled in membership plan for ongoing preventative maintenance services.
Completed comprehensive air conditioning tune-up and maintenance service on R410A cooling system. Performed full system diagnostics using digital manifold gauges, recording operating pressures and temperatures to verify proper refrigerant charge and system performance. Low-side pressure measured at 99.5 psi with 13.7°F superheat, high-side pressure at 205.2-206.2 psi with 9.8°F subcooling, confirming system is operating within manufacturer specifications. All measurements indicate proper refrigerant charge levels and efficient heat transfer. System found to be in good working condition with no deficiencies noted during inspection.
Completed comprehensive cooling system tune-up and preventative maintenance inspection. Accessed and evaluated blower assembly, noting accumulated dust and debris on centrifugal fan wheel and hub requiring attention during routine maintenance cycle. All system components inspected and verified operational per manufacturer specifications.
Completed preventative maintenance on 16-year-old air conditioning system. Inspected and documented blower assembly showing dust accumulation on squirrel cage fan blades, indicating normal operational wear. Performed system diagnostics using digital manifold gauge, recording refrigerant pressures and verifying proper operation of outdoor condensing unit.
Completed comprehensive cooling system tune-up on rooftop-mounted Armstrong air conditioning unit and associated wall-mounted components. Performed standard preventive maintenance procedures including inspection of condenser unit, refrigerant line sets, electrical connections, and outdoor equipment installation integrity. All systems evaluated and found operating within normal parameters, with photographic documentation captured for service records.
Performed comprehensive annual maintenance on a 5-year-old Coleman split system air conditioning unit, model CF24BXA1A. Conducted complete system inspection including condenser fan motor and blade assembly, verified proper operation of all mechanical components, and confirmed unit specifications for R410A refrigerant system. All components found in satisfactory working condition with normal wear patterns consistent with equipment age.
Responded to service call for 15-year-old central air conditioning unit experiencing loud humming noise audible from front of house. Upon arrival, inspected outdoor condenser unit positioned against exterior wall and conducted diagnostic assessment of compressor, fan motor, and electrical components. Identified source of excessive noise, performed necessary repairs to eliminate humming sound, and verified system returned to normal operating noise levels with proper cooling function restored.
Performed comprehensive AC tune-up on six-year-old cooling system. Conducted full system diagnostics using refrigerant manifold gauge to verify operating pressures and temperatures, inspected outdoor condenser unit including coil condition and fan operation, checked electrical connections and condensate drainage system. All components found operating within normal parameters with no deficiencies noted; system performance confirmed satisfactory.
Completed annual cooling maintenance on 11-year-old residential air conditioning system as part of recurring Home Plan service. Performed comprehensive tune-up including inspection of blower housing, heat exchanger components, and internal mechanical systems, all of which showed clean condition with no visible deterioration. Recorded system performance measurements including temperature differential of 22.8°F and supply air temperature of 73.59°F, confirming proper cooling operation and refrigerant charge levels within manufacturer specifications.
Performed routine maintenance on a 17-year-old Lennox air conditioning system. Completed comprehensive tune-up including system diagnostics using refrigerant manifold gauges to verify operating pressures and temperatures across all refrigerant lines. All measured values were within normal operating parameters, confirming proper system performance and refrigerant charge levels.
Completed routine air conditioning maintenance on outdoor condensing unit located in backyard. Performed comprehensive system inspection including cleaning of condenser fan blade assembly and motor hub, verified proper blade alignment and clearances, checked refrigerant pressures, tested electrical connections and capacitor operation, and confirmed unit is operating within manufacturer specifications. System is functioning properly with no issues found.