With five generations of knowledge, Verne & Ellsworth Hann has provided our clients in Shaker Heights with outstanding customer service. When you need trained HVAC technicians or certified plumbing services, you can count on Verne & Ellsworth.
Northeast Ohio’s Heating, Air Conditioning, Boilers, Plumbing experts. If you’re having problems with your HVAC or plumbing, contact us today!

Reliable Heating Replacement & Repair
The average winter temperature for Shaker Heights is 36 degrees. When the weather is that cold, you need to know you can count on your heating unit to do its job. Inevitably, heating units will break down, but you can always count on Verne & Ellsworth for reliable heating services. We can install, replace, repair, and maintain your home’s heating unit.Â
Our qualified heating technicians have decades of experience with:
- Gas and electric furnaces: These are tried and tested methods for keeping your home warm. With reliable fuel sources and the ability to share your AC’s existing ductwork, a furnace is a fantastic option for heating your home.
- Boilers: Boilers heat the home by boiling water, piped throughout to radiate heat into the air. This centuries-old device uses one of the most reliable methods around.
- Heat pumps: Heat pumps are a modern way to heat your home. They work without external heat sources, such as furnaces and boilers, and can pull heat from the air, ground, or a nearby water source.Â
Comprehensive Cooling & AC Services
When the humidity spikes and the temperature approaches 90 degrees, it’s no time for your AC to stop. No matter the issue, you can count on Verne & Ellsworth for trustworthy cooling services. Our certified AC technicians can install, replace, repair, and maintain your home’s AC unit.
We have decades of knowledge in:
- Ductless mini-splits: A ductless mini-split gives you complete control over your home’s temperature without the cumbersome ductwork of traditional units. A ductless mini-split cools your home through an individual unit mounted to the wall in each room.
- High-velocity ACs: High-velocity AC units are a perfect option for historic homes in the Shaker Heights area. Instead of ductwork, they use small, flexible tubing to pipe air throughout your home.
Air Quality & Ductwork Services in Shaker Heights
The air quality in your home has a significant impact on your health and well-being. This is why Verne & Ellsworth is proud to work with units such as:
- Air scrubbers and cleaners: These units keep the air free of germs and allergens, keeping your lungs happy and healthy.
- Carbon monoxide detection: These can be life-saving devices for those using gas or oil furnaces.
- Whole-house humidifiers: Dry air pulls moisture from anywhere it can. Protect your home, furniture, and skin with a whole-house humidifier.
- Whole-house dehumidifiers: Too much moisture in the air can lead to mildew and mold issues. A dehumidifier is an easy way to prevent this.Â
Top-Rated Plumbing Services
Malfunctioning plumbing is a fast way to ruin your day. You can count on Verne & Ellsworth when you need qualified plumbing services. We’ll keep your plumbing running smoothly with such services as:
- Water heaters: We can install or repair your traditional or tankless water heaters.
- Water lines: We can install or repair your water lines to keep your potable water flowing.Â
- Gas lines: We can pipe, repair, and test your gas lines to ensure your home’s safety.
- Drain snaking: We’ll keep your home draining smoothly, removing any pesky clogs you may face.
Schedule With Verne & Ellsworth Hann in Shaker Heights
One of the oldest family-run businesses in the area, Verne & Ellsworth has won the Angi Super Service Award and the Best of the Heights Award. We are committed to outstanding customer service, professionalism, and integrity. When our licensed and insured technicians set foot on your property, you can rest assured the job will be done right.
Contact our team today to request a free estimate or to schedule services in Shaker Heights.
Recent Jobs and Reviews in Shaker Heights, OH
Job Locations and Reviews
Completed routine maintenance and tune-up on a 4-year-old Bryant air conditioning system. Performed comprehensive inspection of the air handler unit located in attic space, verified proper operation of all components, and checked manufacturer specifications. System found to be operating within normal parameters with no deficiencies noted. All safety labels and equipment markings confirmed present and legible. This service included standard preventative maintenance procedures to ensure continued efficient operation of the cooling system.
Conducted site assessment for add-on air conditioning system installation at duplex property with separate upper and lower units. Evaluated existing HVAC infrastructure including Ultra 80 furnace, electrical panel capacity, ductwork configuration, and mechanical room layout to determine feasibility and requirements for dual AC system integration. Documented current equipment conditions and spatial constraints in basement utility area to prepare comprehensive replacement estimate.
Conducted on-site estimate for boiler system replacement. Documented existing heating distribution system including cast iron radiators and baseboard radiators throughout residence, noting accumulation of dust and debris on heating units requiring attention during installation phase.
Completed full HVAC system replacement including removal and installation of furnace, evaporator coil, condenser unit, and thermostat. Added return air grille (1410) to bottom of furnace for proper airflow. Coordinated crane service to lift and position condenser unit on rooftop, ensuring secure mounting and proper clearances. All ductwork connections completed with sealed plenums, refrigerant lines installed and charged to manufacturer specifications, condensate drainage verified, and electrical connections made per code requirements. System tested and confirmed operational with proper temperature differential and airflow throughout.
Completed furnace maintenance and addressed humidifier leak issue. Performed system diagnostics with manometer reading of 191, inspected internal components with access panel removed, and serviced unit to resolve excessive water leakage from humidifier system.
Performed diagnostic evaluation of existing Bradford White tanked water heater in residential basement mechanical room. Assessed unit condition, noting manufacturer date of 3-30-26 on tank exterior, proper earthquake strap installation, and functional gas control valve assembly. Documented current system configuration including copper supply piping, expansion tank mounting, and overall installation compliance. Provided customer with comprehensive replacement options comparing conventional tank water heater versus tankless system installation to meet their specific needs and preferences.
Completed annual maintenance on 8-year-old residential steam boiler system. Performed comprehensive combustion analysis using digital analyzer, recording flue gas temperature, CO2 levels, and system efficiency parameters. Inspected all safety controls, pressure gauge operation, shut-off valves, and piping connections. Verified proper water level, cleaned and tested low water cutoff, and examined all electrical connections and control board functionality. System operating within manufacturer specifications with no deficiencies noted.
Completed full steam boiler system replacement in mechanical room. Installed new steam boiler with associated components including backflow preventer, automatic feeder, and White-Rodgers digital thermostat. Replaced existing Hartford loop due to multiple leak points. Reused existing vaporstat and connected to 3" black pipe supply and 3" main. Replaced three smaller-style steam vents on return lines. Removed improperly installed main vent that was tapped directly into pipe, repaired piping to meet proper installation standards, and installed new main vent in correct configuration. All copper and black iron piping connections completed with proper shut-off valves. System tested and operational upon completion.
Completed comprehensive annual heating maintenance on two 9-year-old Crown boiler systems. Performed full tune-up procedures including inspection of all mechanical components, burner assembly, heat exchanger, circulator pumps, and control systems. Verified proper operation of Honeywell control unit, checked pressure gauge readings, and tested all safety controls and electrical connections. Cleaned and serviced both units, inspected copper piping and flexible conduit connections, and confirmed systems are operating at optimal efficiency for the heating season.
Responded to service call for malfunctioning 3-year-old heat pump displaying error code 57-41 (P1 open lockout). Upon arrival, diagnosed refrigerant system issue and utilized refrigerant scale to verify charge levels and perform necessary adjustments to restore proper operation and clear lockout condition.
Conducted comprehensive on-site assessment of existing radiator system throughout residence. Evaluated all radiator units to identify those requiring removal and replacement based on condition, performance, and functionality. Documented current system configuration and specific units needing service through detailed photographic records of heating equipment and thermostat locations.
Responded to a clogged bathroom sink in a seventy-year-old home. Successfully cleared the drain obstruction, restoring proper water flow and drainage function. Tested the fixture to confirm the sink was draining properly with no backup or slow drainage issues.
Completed comprehensive tune-up and maintenance service on two gas-fired boiler systems. Primary unit serviced was a Slant/Fin Sentinel SE-70 EDP gas-fired boiler. Performed standard maintenance protocol including combustion analysis, temperature differential testing across supply and return lines, inspection of gas connections and flexible conduits, verification of relief valve settings and maximum operating parameters, and visual inspection of all associated piping and controls. Documented system operating temperatures and confirmed proper functionality of both heating units.
Responded to reported valve leak on plumbing assembly. Upon inspection, identified active leak at valve fitting connection point on wall-mounted system. Placed absorbent material beneath assembly to contain water discharge during evaluation. Assessed valve condition, surrounding pipe connections, and mounting hardware for integrity. Documented existing conditions including mineral deposits and water staining in collection pan, indicating ongoing leak activity. Captured photographic evidence of valve assembly configuration and leak source for service records.
Removed existing boiler system and relocated holding tank to corner of basement utility area. Installed new 75-gallon power vent water heater on concrete platform with proper venting configuration. Connected copper supply lines, installed expansion tank, and completed all electrical conduit runs to code. Unit positioned against concrete block wall with PVC exhaust venting routed through ceiling infrastructure. All plumbing connections pressure tested and verified operational.
Conducted on-site boiler estimate in basement mechanical room. Evaluated existing heating system including modern boiler unit with digital display, extensive PVC piping network with multiple zone valves, aged gas supply line with Boston flexible connector, and associated plumbing infrastructure. Documented current system configuration and component conditions through photographic assessment for replacement proposal.
Completed scheduled maintenance visit on commercial steam boiler system. Performed comprehensive inspection of gas valve assembly, ignition controls, and heat exchanger components. Examined refractory elements within combustion chamber, confirming proper alignment and structural integrity of ceramic insulation components. All safety controls tested and verified operational, with system operating within manufacturer specifications at time of departure.
Completed annual Home Plan inspection on steam boiler system. Performed comprehensive examination of heat exchanger components, burner assembly, and internal mechanical systems. Heat exchanger fins showed significant accumulation of dust, debris, and surface oxidation requiring attention during next maintenance cycle. All burner rollers and mounting hardware inspected and found to be structurally sound with normal wear patterns on protective coatings. System operational and safe for continued use.
Responded to service call for leaking main water valve in basement. Upon arrival, inspected the main shut-off valves and plumbing manifold system. The chrome-handled wheel-style shut-off valves showed signs of active leaking at the connection points. Documented existing conditions including the PEX manifold distribution system, copper supply lines, and main valve assembly. Performed assessment of the leak source and surrounding plumbing infrastructure to determine necessary repairs.
Completed comprehensive annual heating maintenance on century-old boiler system. Performed thorough inspection revealing significant internal corrosion, rust staining, and mineral deposit accumulation within combustion chambers and heat exchanger sections. Verified system pressure, tested all safety controls, and documented equipment condition with photographic evidence for maintenance records.