Verne & Ellsworth Hann excels in HVAC and plumbing services in Mayfield Heights, OH. Our team has earned the Angi Super Service Award and the Best of the Heights Award, a testament to our outstanding customer service. Committed to excellence, they ensure homes and businesses enjoy optimal comfort and functionality.
Schedule HVAC or plumbing services by contacting Verne & Ellsworth Hann at (216) 932-9755 for unparalleled expertise and care.

Top-Rated Heating & Cooling Services
Verne & Ellsworth Hann specializes in comprehensive heating and cooling solutions. Our expertise spans heating installation, replacement, repair, or maintenance and cooling system installation, replacement, repair, or maintenance.Â
- Ductless mini-splits: Ideal for homes without traditional ductwork, our ductless mini-split systems offer efficient temperature control. They’re perfect for targeted heating and cooling in specific rooms or areas.
- Heat pumps: These versatile systems provide heating and cooling, ensuring year-round comfort. Our team expertly installs and maintains heat pumps for optimal energy efficiency.
- Furnaces: Choose from our wide range of gas and electric furnaces. We ensure your home stays warm and cozy during colder months with reliable installation and maintenance services.
- Boilers: We prioritize boiler services, recognizing their importance in many homes. Whether you need a new installation or urgent repairs, our team is ready to provide prompt, expert service.
Air Quality & Ductwork Services in Mayfield Heights
Verne & Ellsworth Hann provides comprehensive air quality and ductwork services in Mayfield Heights, encompassing installation, replacement, repair, and maintenance.
- Air scrubbers: Enhance your indoor air quality with our state-of-the-art air scrubbers. These systems effectively remove pollutants, ensuring a healthier environment in your home or office.
- Air purifiers: Our air purifiers capture and eliminate airborne contaminants. They are critical for maintaining clean air, reducing allergens, and improving overall health.
- Whole-house humidifiers: Balance the humidity levels in your home with our whole-house humidifiers. They improve air quality and protect your home’s structure and furnishings from dry air damage.
Ensure a healthier environment for your home or business with Verne & Ellsworth Hann. Schedule air quality services today at (216) 932-9755.
Professional Plumbing Services
At Verne & Ellsworth Hann, we provide expert plumbing services to address a wide range of needs in Mayfield Heights.
- Water heaters: Our team specializes in installing, repairing, and maintaining water heaters. Whether you have a traditional or tankless system, we ensure a consistent and efficient hot water supply.
- Water lines: We handle everything from installation to repair of water lines. Our services guarantee a reliable and safe water supply, minimizing disruptions and potential damages.
- Gas lines: Safety is paramount when dealing with gas lines. Our skilled plumbers provide secure installation and maintenance services, ensuring your gas lines function correctly and safely.
- Bathroom & kitchen plumbing: We offer comprehensive solutions for bathrooms and kitchens. Our expertise covers all your plumbing needs, from fixing leaks to installing new fixtures.
Book a plumbing appointment now by calling (216) 932-9755. Our team provides efficient and reliable services for your home or business.
Choose Verne & Ellsworth Hann in Mayfield Heights, OH
Choose Verne & Ellsworth Hann for your HVAC and plumbing needs and experience working with a team committed to professionalism and integrity. Our licensed and insured technicians bring expertise and a dedication to quality service. Trust in our skilled professionals for reliable, efficient, and safe solutions, ensuring your comfort and satisfaction.
With Verne & Ellsworth Hann, you’re choosing a partner invested in the long-term well-being of your home or business. Discover unparalleled service with Verne & Ellsworth Hann.
Contact our team today at (216) 932-9755 to schedule HVAC or plumbing appointments.
Verne and Ellsworth Hann has completed 20 jobs in Mayfield Heights, OH between March 2026 and June 2026. The most recent job was on June 17, 2026.Recent Jobs and Reviews in Mayfield Heights, OH
Mayfield Heights, OH at a glance
Job Locations and Reviews
Responded to service call for older Crown boiler with active leak. Applied boiler sealer to address dripping issue as temporary measure. Assessed existing boiler system including copper piping network, expansion tank, and venting configuration. Provided replacement estimate options including standard boiler replacement and combination boiler upgrade alternatives for customer consideration.
Conducted on-site assessment for HVAC system replacement in residential basement installation. Evaluated existing furnace unit with heat exchanger and connected ductwork, documented current system configuration including flexible metallic ductwork routing and utility room layout with water heater proximity. Confirmed customer availability and provided comprehensive replacement estimate for new equipment installation.
Performed comprehensive air conditioning tune-up on a fifteen-year-old system that was operating without issues. Inspected and evaluated the air filter, which showed moderate dust and dirt accumulation throughout the pleated media, indicating normal use over its service period. Connected manifold gauge set to measure system pressures and verify refrigerant charge levels, confirming the unit was functioning within proper operating parameters.
Responded to service call for non-functional tanked water heater with reported gas leak and occasional "snowing" condition in 70-year-old residence. Upon arrival, inspected the white cylindrical water heater unit and surrounding plumbing connections, including copper piping, brass fittings, galvanized ductwork, and expansion tank assembly. Documented existing installation configuration showing multiple pipe connections at top of unit, adjacent blue water treatment system, and utility room conditions. Due to safety concerns regarding the reported gas leak, further diagnostics and corrective action were required to address both the operational failure and hazardous gas condition.
Performed comprehensive air conditioning tune-up on 15-year-old system including full inspection of blower assembly, which showed significant dust and debris accumulation on blower wheel fins and motor housing. Conducted combustion analysis and temperature differential measurements, recording supply air temperature of 330.5°F and achieving 15.7°F temperature split with CO2 levels at 0.66%, confirming proper system operation and efficiency within acceptable parameters.
Conducted on-site evaluation for complete HVAC system replacement. Assessed existing two-stage furnace unit in basement mechanical room, noting current configuration with PVC venting system and connection to existing ductwork. Inspected exterior utility connections and identified weathered condensate drainage lines showing significant deterioration and staining. Documented equipment specifications, spatial constraints, and existing infrastructure to provide comprehensive replacement estimate options. Coordinated arrival time and confirmed appointment for presenting three equipment replacement proposals to customer.
Completed spring air conditioning tune-up on one-year-old Bryant condenser unit. Performed comprehensive system inspection including refrigerant levels, electrical connections, capacitor testing, and airflow verification. Unit found to be operating within manufacturer specifications with no deficiencies noted.
Completed scheduled recurring cooling system maintenance on residential outdoor condensing unit located at rear of property. Performed comprehensive inspection of unit exterior, verified proper placement on pad with adequate clearance, confirmed electrical connections secure, and documented system condition with photographic records. Unit operational and functioning within normal parameters upon completion of service visit.
Responded to a request to disconnect and cap an existing dryer gas line due to safety concerns at a 73-year-old residential property. Upon arrival, found the gas line corroded onto the dryer connection, requiring careful disconnection to prevent damage to the existing gas piping system. Successfully disconnected the corroded gas line, installed appropriate gas line cap to ensure safe termination, and verified all connections were secure with no leaks detected. Gas shut-off valves were confirmed operational and left in the closed position for safety.
Performed comprehensive preventive maintenance on 7-year-old air conditioning system. Conducted system performance diagnostics using refrigerant manifold gauge, verifying R410A refrigerant pressures and temperatures within manufacturer specifications. Completed routine maintenance procedures including inspection of condenser unit, coil cleaning assessment, and overall system operational check to ensure optimal cooling performance for the season.
Completed maintenance plan renewal for residential HVAC system. During inspection, observed frost accumulation on evaporator coil and condensation on supply air grille, indicating potential airflow restriction or refrigerant issue that will require monitoring. Customer advised of maintenance plan options and coverage details.
Performed annual maintenance tune-up on 1-year-old Bryant air conditioning system. Upon arrival, noted that the decorative Bryant nameplate disc (5-6" diameter) from the top of the condensing unit had blown off due to wind. Conducted comprehensive system diagnostics using Fieldpiece SMAN refrigerant manifold and micron gauge, verifying refrigerant pressures, temperatures, and superheat/subcooling values to ensure proper system operation. All measured parameters were within manufacturer specifications. Completed standard maintenance procedures including inspection of electrical connections, capacitor testing, and airflow verification. System operating normally with no performance issues detected.
# AC Maintenance Completed
Performed comprehensive air conditioning maintenance on outdoor condensing unit. Connected digital manifold gauge set with refrigerant hoses to service ports to measure system pressures and temperatures. Utilized Fieldpiece SMAN diagnostic equipment to evaluate refrigerant charge levels, superheat, and subcooling values. Readings indicated system operating parameters were within acceptable range at 212.1°F discharge temperature with corresponding pressure readings of 313 PSIG. Conducted electrical testing with digital multimeter to verify proper voltage and amperage to compressor and condenser fan motor. All electrical components tested within manufacturer specifications. Inspected condenser coil fins for debris and damage, confirmed adequate airflow through unit. Verified fan motor operation and blade condition. System operating efficiently with no refrigerant leaks detected and proper cooling capacity restored.
Completed routine home plan plumbing inspection on a 10-year-old Defender Safety System tanked water heater. Assessed overall unit condition, verified proper operation of temperature controls and pressure relief valve, inspected all visible plumbing connections including copper supply lines and brass fittings, and documented equipment status with photographic records. Unit found to be operational with normal age-related wear present.
Completed routine maintenance on residential heating and cooling system as part of annual tune-up service. Performed comprehensive inspection of furnace and air conditioning unit, verifying all components operating within normal parameters. Conducted combustion analysis on heating system, confirming proper oxygen levels at 13.7%, zero carbon monoxide detection, and carbon dioxide readings at 4.1% with supply temperatures measuring 83.5°F. Inspected condenser unit, checked refrigerant levels, cleaned coils, and verified electrical connections. All safety controls tested and found functioning correctly. No deficiencies noted during inspection; system ready for seasonal operation.
Completed scheduled heating tune-up and preventative maintenance on residential furnace system. Performed comprehensive inspection of blower assembly, verifying proper operation and cleanliness of squirrel cage fan with no debris accumulation or blade damage noted. Inspected gas burner assembly with blue flame burners, confirmed proper ignition sequence, and verified all electrical connections including control wiring and gas valve operation. All components found to be functioning within normal parameters with system cleared for continued operation through heating season.
Performed annual maintenance on 4-year-old furnace that was operating properly. Conducted comprehensive system diagnostics including temperature readings (94°F) and humidity levels (68%). Inspected ventilation components and completed all required tune-up procedures to manufacturer specifications.
Diagnosed and repaired leaking TOTO toilet in 43-year-old residential bathroom by replacing deteriorated flapper valve and addressing mineral buildup in tank. Inspected supply line connections and floor mounting to ensure proper installation, eliminating leak and restoring proper flush functionality.
Performed annual maintenance on 8-year-old hot water boiler system. Inspected burner assembly confirming proper flame pattern with characteristic blue-purple combustion indicating efficient operation. Documentation and service plan registration completed pending administrative processing.
Performed scheduled Home Plan Heating Tune-Up service on the heating system. Inspected blower wheel assembly for proper operation and cleanliness. Verified proper ignition sequence and examined burner assembly with flames present, confirming normal operation of the gas furnace. All electrical connections were inspected and found to be secure with no signs of deterioration.